Factory Setup Menu Options
Each Factory menu option is described below. Many of the screens are common to several
CE4 products and are shared between them.
Factory Setup Menu Options
1. Factory Service:
a. Clear Logs (Factory)
The clear logs function erases the internal log and will displays a confirmation dialog
briefly.
b. Leakage Calibration (Factory)
The Leakage Calibration menu recalculates the leakage and current offsets by
measuring the current and leakage with no detonators connected. It functions in the
same fashion as the leakage test screen except that it initially shows a leakage
calibrate dialog briefly and then proceeds to the leakage screen.
c. Reset Service Date
o This function will allow the user to reset the service schedule.
d. IO Setup (Factory) (Only available in the Bench Ranger)
o The IO Setup function is used to setup experimental IO parameters.
e. Migrate NFC Key
o The Migrate NFC Key function is used to migrate an outdated key to the
new structures.
f. Benches (Only available in the Base Ranger)
o Used to enable more than one Bench box. (This will require a ticket).
2. Start Self-Test
The option allows Ranger to perform self test
3. Experimental Menu (Factory)
This menu option will contain any experimental functions that are required in engineering only.
4. Storage Mode
Press Key to select Storage Mode
When the battery capacity is more than 50%, the CE4
Tagger will discharge the battery by activating
additional battery draining functions such as the
heating pad, to accelerate the discharge level to the
required 50% charge level, and
When the battery capacity is less than 50%, it will
prompt the user to connect a charger to attain the required 50% charge level.
Only Storage Mode will be accessible without a Web Ticket. All other Menu items will need
a Web Ticket to be accessed.