System Description

UTM-00355 | Rev 2
Page 247 of 261
DetNet South Africa Copyright © 2022
Fault Condition Error Screen Troubleshooting / Remedial Action
Current limiter has
activated
This error may trigger at any point during the testing,
programming or firing process. The error points to excessively
high leakage or a short circuit on the channel. The Tagger may
be used to identify the source of leakage using the binary search
technique. If this error occurs after programming the user will
need to reprogram the channel
Untagged detonator
found
Test All
When the Ranger detects a detonator that still has the internally
recorded factory ID, which means that it has not been
successfully tagged, it will trigger the untagged warning.
The Tagger may be used to find the untagged detonator on a
string using the binary search technique.
Once the untagged detonator has been found, it must be tagged
with a delay or location (or both) as per the blast plan.
Untagged test
Test Single det
Wrong / Invalid Card
This error will be displayed either when the user scans a Red
BlastCard when a Yellow BlastCard is expected or vice versa.
The error will also be displayed if the BlastCard is invalid. The
user must scan the correct BlastCard or replace the BlastCard if
it is invalid or not working correctly