System Description

UTM-00355 | Rev 2
Page 89 of 261
DetNet South Africa Copyright © 2022
Advanced
The Advanced Mode option is more complex than the Basic Mode as it allows for multi-primed holes and the user will
need to control several parameters within this mode. To define a hole configuration the “Site Setup” screen will need
to be accessed. The Advanced (A) Tagging option also allows the user to tag detonators using Detonator Label
methods as follows:
Method 1: {NNNNN} {N}, a hole number and det number is assigned.
DigiShot Label
Method 2: {NNN} {NNN} {N} a group number depicted as Row number, hole number and det number is
used.
Method 3: {AA} {NNN} {N}, a user configurable 2 letter group number, hole number and det number is
assigned.
Method 4: {A} {NNNNN} {N}, a user configurable single letter group number, hole number and det number is
assigned.
Tag by Plan
With the Planned (P) tagging option, both the location and a delay will be written into the detonator.
The data written into the detonator is taken from a plan downloaded into the CE4 Tagger via ViewShot.
When exporting the design from ViewShot as the connection sequence and blasthole numbers will be exported to the
tagger.
Manual locations can also be deployed separately from delays by using Advanced mode with “Assign Location” setting
checked. This feature can be used when the delays are not yet known.
Delays can be deployed to the tagged detonators later in Planned mode, using the available plan based on location
matching.