Operators Manual
Table Of Contents
- California Proposition 65 Warning and Engine Idle Notice
- Forward
- To the Operator
- Caution Summary
- Engine Identification
- Operating Instructions for Starting the Engine
- First Time Start Preparations
- System Checks
- Starting the Engine for the First Time
- Starting the Engine
- Running the Engine
- Stopping the Engine
- Emergency Jump Starting
- Routine Engine Start
- Monitoring the Engine Operation
- Changing the Idle Speed
- Shutting Down the Engine after High Load Operation
- Emergency Running Mode
- Stop Engine Override Option
- Cold Weather Operation
- First Time Start Preparations
- Detroit Diesel Electronic Controls (DDEC) System
- Engine Brake System
- Engine Systems
- EPA07 Aftertreatment Device
- EPA10 Aftertreatment System
- GHG14 Aftertreatment System
- GHG17 Aftertreatment System
- Diesel Exhaust Fluid Information
- Aftertreatment Device Operating Requirements
- EPA10 Diesel Exhaust Fluid (DEF) Purge Cycle
- EPA10/GHG14/GHG17 Diesel Exhaust Fluid Tank
- Aftertreatment Maintenance
- Performing a Parked Regeneration - EPA07
- Performing a Parked Regeneration - EPA10/GHG14
- Performing a Parked Regeneration
- Hazardous Applications
- Service Record
- Instrument Panel Lamps
- Diesel Exhaust Fluid Level Warning Lamps
- Aftertreatment System Driver Notifications and Actions
- DEF Post-Run Indicator Lamp
- Preventive Maintenance Intervals
- EPA07/EPA10/GHG14/GHG17 Preventive Maintenance Tables - 93K222(CK-4) and 93K223(FA-4)
- EPA07/EPA10/GHG14/GHG17 Preventive Maintenance Tables - 93K218(CJ-4)
- EPA07/EPA10/GHG14/GHG17 Preventive Maintenance Tables for Recreational Vehicles
- Routine Preventive Maintenance
- Monitoring the Lubricating Oil
- Monitoring the Lubricating Oil Filter
- Monitoring the Cooling System
- Inspection of the Radiator
- Monitoring the Cooling System Filter
- Monitoring the Fuel Filters
- Adjusting the Valve Lash
- Monitoring the Belt Tensioner
- Poly-V-Belt Inspection
- Monitoring the Serpentine Belts
- Inspection of the Air Intake System
- Monitoring the Air Cleaner
- Monitoring the Exhaust System
- Monitoring the Aftertreatment System
- Inspection of the Air Compressor
- Monitoring the Fuel and Fuel Tank
- Inspection of Hoses and Fittings for Fuel Leaks
- Inspection of the Turbocharger and Charge Air Cooler
- Inspection of the Battery
- Steam Cleaning the Engine
- Inspection of the Battery-Charging Alternator
- Lubricating the Fan Hub
- Checking the Vibration Damper
- How to Procedures
- How to Select Lubricating Oil
- How to Select Lubricating Oil (EPA07)
- When to Change Oil
- How to Replace the Lubricating Oil and Oil Filter
- How to Select Diesel Fuel
- How to Replace the Fuel Filters
- Removal of the Fuel Prefilter - Two-Filter System
- Installation of the Fuel Prefilter - Two-Filter System
- Removal of the Water Coalescer/Final Filter - Two-Filter System
- Installation of the Coalescer/Final Filter - Two-Filter System
- Removal of the Final Filter - Three-Filter System
- Installation of the Final Filter - Three-Filter System
- Removal of the Prefilter - Three-Filter System
- Installation of the Prefilter - Three-Filter System
- Removal of the Water Separator/Coalescer - Three-Filter System
- Installation of the Water Separator/Coalescer - Three-Filter System
- Engine Out of Fuel – How to Restart
- How to Clean an Engine
- Cleaning/Flushing the Cooling System
- Coolant Selections and Maintenance
- Coolant Fill Options
- Coolants for Detroit™ Engines
- Maintenance
- Appendix A - Definitions
- Appendix B - General Coolant Information
- Appendix C - Detroit™ Cooling System Maintenance Products
- How to Replace the Coolant Filter
- Checking the Hoses
- How to Service the Dry Type Air Cleaner
- Customer Assistance
- Detroit Genuine Coolant Engine Products
- Engine Oil Capacities
Monitoring the Exhaust System
Inspect the Exhaust System as follows:
1. Check the exhaust manifold retaining bolts and other connections for
tightness.
2. Check the exhaust pipe rain cap for proper operation, if so equipped.
Monitoring the Aftertreatment System
A Check Engine Indicator or mileage/time intervals indicate when ash cleaning is
required. Use DETROIT Diesel Corporation's authorized DPF cleaning procedure.
Failure to follow this procedure could result in engine and/or aftertreatment
damage, causing degraded vehicle performance including excess fuel consumption
and decreased engine life. Estimated intervals shown are documented in following
section; Refer to section "Preventive Maintenance Intervals".
Periodically the accumulated ash derived from the engine's lubricating oil needs to
be removed from the ATS. This ash does not oxidize in the filter during the
regeneration process and must be removed through a cleaning procedure.
Inspection of the Air Compressor
The air compressor incorporates three of the major systems of a diesel engine (air,
lubrication, and cooling). Inspect the air compressor looking for air, oil, and coolant
leaks.
Monitoring the Fuel and Fuel Tank
To prevent fuel and fuel tank problems, the following measures are recommended:
1. Keep the fuel tank filled to reduce condensation.
2. Before adding fuel, Refer to section "How to Select Diesel Fuel".
3. Refill the tank at the end of each day's operation to prevent condensation
from contaminating the fuel. Condensation formed in a partially filled tank
promotes the growth of microorganisms that can clog fuel filters and restrict
fuel flow.
4. Open the drain at the bottom of the fuel tank every 30,000 miles (50,000
kilometers) to drain off any water and/or sediment.
WARNING: PERSONAL INJURY
To avoid injury from improper use of chemicals, follow the
chemical manufacturer's usage, handling, and disposal
instructions. Observe all manufacturer's cautions.
Routine Preventive Maintenance
144 All information subject to change without notice.
Copyright © 2022 DETROIT DIESEL CORPORATION DDC-SVC-MAN-0189