Operators Manual
Table Of Contents
- California Proposition 65 Warning and Engine Idle Notice
- Forward
- To the Operator
- Caution Summary
- Engine Identification
- Operating Instructions for Starting the Engine
- First Time Start Preparations
- System Checks
- Starting the Engine for the First Time
- Starting the Engine
- Running the Engine
- Stopping the Engine
- Emergency Jump Starting
- Routine Engine Start
- Monitoring the Engine Operation
- Changing the Idle Speed
- Shutting Down the Engine after High Load Operation
- Emergency Running Mode
- Stop Engine Override Option
- Cold Weather Operation
- First Time Start Preparations
- Detroit Diesel Electronic Controls (DDEC) System
- Engine Brake System
- Engine Systems
- EPA07 Aftertreatment Device
- EPA10 Aftertreatment System
- GHG14 Aftertreatment System
- GHG17 Aftertreatment System
- Diesel Exhaust Fluid Information
- Aftertreatment Device Operating Requirements
- EPA10 Diesel Exhaust Fluid (DEF) Purge Cycle
- EPA10/GHG14/GHG17 Diesel Exhaust Fluid Tank
- Aftertreatment Maintenance
- Performing a Parked Regeneration - EPA07
- Performing a Parked Regeneration - EPA10/GHG14
- Performing a Parked Regeneration
- Hazardous Applications
- Service Record
- Instrument Panel Lamps
- Diesel Exhaust Fluid Level Warning Lamps
- Aftertreatment System Driver Notifications and Actions
- DEF Post-Run Indicator Lamp
- Preventive Maintenance Intervals
- EPA07/EPA10/GHG14/GHG17 Preventive Maintenance Tables - 93K222(CK-4) and 93K223(FA-4)
- EPA07/EPA10/GHG14/GHG17 Preventive Maintenance Tables - 93K218(CJ-4)
- EPA07/EPA10/GHG14/GHG17 Preventive Maintenance Tables for Recreational Vehicles
- Routine Preventive Maintenance
- Monitoring the Lubricating Oil
- Monitoring the Lubricating Oil Filter
- Monitoring the Cooling System
- Inspection of the Radiator
- Monitoring the Cooling System Filter
- Monitoring the Fuel Filters
- Adjusting the Valve Lash
- Monitoring the Belt Tensioner
- Poly-V-Belt Inspection
- Monitoring the Serpentine Belts
- Inspection of the Air Intake System
- Monitoring the Air Cleaner
- Monitoring the Exhaust System
- Monitoring the Aftertreatment System
- Inspection of the Air Compressor
- Monitoring the Fuel and Fuel Tank
- Inspection of Hoses and Fittings for Fuel Leaks
- Inspection of the Turbocharger and Charge Air Cooler
- Inspection of the Battery
- Steam Cleaning the Engine
- Inspection of the Battery-Charging Alternator
- Lubricating the Fan Hub
- Checking the Vibration Damper
- How to Procedures
- How to Select Lubricating Oil
- How to Select Lubricating Oil (EPA07)
- When to Change Oil
- How to Replace the Lubricating Oil and Oil Filter
- How to Select Diesel Fuel
- How to Replace the Fuel Filters
- Removal of the Fuel Prefilter - Two-Filter System
- Installation of the Fuel Prefilter - Two-Filter System
- Removal of the Water Coalescer/Final Filter - Two-Filter System
- Installation of the Coalescer/Final Filter - Two-Filter System
- Removal of the Final Filter - Three-Filter System
- Installation of the Final Filter - Three-Filter System
- Removal of the Prefilter - Three-Filter System
- Installation of the Prefilter - Three-Filter System
- Removal of the Water Separator/Coalescer - Three-Filter System
- Installation of the Water Separator/Coalescer - Three-Filter System
- Engine Out of Fuel – How to Restart
- How to Clean an Engine
- Cleaning/Flushing the Cooling System
- Coolant Selections and Maintenance
- Coolant Fill Options
- Coolants for Detroit™ Engines
- Maintenance
- Appendix A - Definitions
- Appendix B - General Coolant Information
- Appendix C - Detroit™ Cooling System Maintenance Products
- How to Replace the Coolant Filter
- Checking the Hoses
- How to Service the Dry Type Air Cleaner
- Customer Assistance
- Detroit Genuine Coolant Engine Products
- Engine Oil Capacities
Checking the Coolant Level (Hot Check)
Check the coolant levels as follows:
1. Allow the engine to run for approximately five minutes at a moderate speed.
2. After the coolant temperature reaches 50°C (122°F), recheck the coolant
level in the surge tank.
WARNING: HOT COOLANT
To avoid scalding from the expulsion of hot coolant, never remove
the cooling system pressure cap while the engine is at operating
temperature. Wear adequate protective clothing (face shield,
rubber gloves, apron, and boots). Remove the cap slowly to
relieve pressure.
3. Add more coolant if necessary. Open the heater valves before adding
coolant.
4. Do not close the heater valves until the engine has been running briefly and
the coolant level is again checked and corrected as necessary.
Monitoring the Engine Operation
While the engine is operating, monitor the battery charge indicator light and the oil
pressure. Excessive idling should be avoided.
Monitoring the Battery Charging System
The battery charge indicator light must go out once the engine starts. If the
indicator light comes on while the engine is running, do the following:
1. Shut down the engine.
2. Test the charging system, per OEM guidelines.
WARNING: BATTERY EXPLOSION
To avoid injury from battery explosion when jump starting the
engine, do not attach the cable end to the negative terminal of the
disabled battery.
3. If necessary, visit the nearest authorized dealer to have the alternator voltage
and output checked.
4. Do a load test on the batteries.
5. Replace components as needed.
DD Heavy Duty Platform Operators Manual