24.1 REPLACING OIL PLUG WITH OIL SAMPLE VALVE
Replace oil plug with oil sample valve as follows:
1. Using a 17 mm Allen tool remove the Allen head plug from the oil priming port on the
oil coolant module.
2. Install the oil sample valve onto the oil c oolant module. Torque to 80 N·m (59 lb·ft).
All information subject to change without notice.
DDC-SVC-MAN-0081 20 10 Copyright © 2010 DETROIT DIESEL CORPORAT ION 24-3