6.1 DESCRIPTION AND OPERATION OF DD15 & DD16 WATER MANIFOLD
AND RELATED COMPONENTS
Coolant flows from the cylinder head through an opening next to each exhaust port and into the
water manifold in the DD15 engine. The water manifold i s attached to the cylinder head by a
total of nineteen bolts, including two that are shared with the coolant outlet elbow. Two 3-port
gaskets are used between the water manifold and the cylinder head.
1. Connecting Pipe 7. Bolt
2. Water Man ifold 8.Plug
3. Bolt 9. Bolt
4. Bol t
10. Bolt
5. Coolan t Outlet Elbow
11. Gas
ket
6. Gask
et
Figure 6-1 DD15 & DD16 Water Manifold and Related Parts
All information subject to change without notice.
DDC-SVC-MAN-0081 20 10 Copyright © 2010 DETROIT DIESEL CORPORAT ION 6-3