OPERATING INSTRUCTIONS FOR A FIRST TIME START
When preparing to start a new or newly
overhauled engine which has been in
storage, p e rform all of the operations
listed below. Failure to follow these
instructions may result in serious
engine damage. Before a routine start,
see th e “Daily” checks for y our engine
in the MAINTENANCE section.
PERSONAL INJURY
Diesel engine exhaust and some
of its constituents are known to
the State of California to cause
cancer, birth defects, and other
reproductive harm.
Always start and operate an
engine in a well v entilated
area.
If operating an engine in
an enclosed area, vent the
exhaust to the outside.
Do not modify or tamper
with the exhaust system or
emission control system.
PERSONAL INJURY
To avoid injury when working
near or on an operating engine,
remove loose items of clothing
and jewelry. Tie back or contain
long hair that could be caught in
any moving part causing injury.
System Checks
Perform the following system checks
before startin g for the rst time.
Cooling System Checks
Check the cooling system as follows:
1. Make sure all drain cocks in
the cooling system are installed
(drain cocks are often removed
for shipping) and are closed
tightly.
2. Remove the radiator pressure
control cap and ll with genuine
Detroit Diesel Power Cool
antifreeze or an equivalent quality
ethylene glycol or propylene
glycol-base antifreeze solution
in the required concentration.
In extremely hot environments,
properly inhibited water may
be used in the summer. Keep the
coolant level at the bottom of the
ller neck to allow for expansion
All information subject to change without notice. (Rev. 01/04) 15
DDC-SVC-MAN-0058 Copyright © 2004 DE TROIT DIESEL CORPORATION