User Manual
OPERATING INSTRUCTIONS FOR A FIRST TIME START
Emergency Jump Starting
The DDEC IV system operates on
12 or 24 volts DC. If a n engine with
an electric starting motor requires
emergency jump starting, do not
exceed 32 volts DC.
NOTICE:
Jump starting with voltages greater
than those indicated or reversing
battery polarity may damage the
Electronic Control Module.
BATTERY EXPLOSION
To avoid injury from battery
explosionwhenjumpstartingthe
engine, do not attach the cable
end to the negative terminal of
the d isabled battery.
NOTICE:
Failure to connect jumper cable s
in the proper sequence can resu lt
in alternator and/or equipment
damage.
Before attemp ting to jump start the
engine, make sure the jumper cables
are connected properly (positive to
positive, negative to negative ground)
and in the proper sequence (negative
to negative ground last).
Battery Explosion and Acid Burn
To avoid injury from battery
explosion or contact with battery
acid, work in a well ventilated
area, wear protective clothing,
and avoid sparks or flames nea r
the battery. If you come in contact
with battery acid:
□ Flush your skin with water.
□ Applybakingsodaorlimeto
help neutralize the acid.
□ Flush your eyes with water.
□ Ge t medical attention
immediately.
22 All information subject to change without notice. (Rev. 01/04)
DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION