For example, the Rear PTO speed with a DT12-DA (DH) Split Low with the 1:1 PTO Ratio would be:
(Engine RPM) x (Engine:PTO Ratio) = 850 rpm x 0.78 = 663 rpm
Similarly, the Rear PTO speed with a DT12-OC (OHE & OV) Split High with the 1:1.32 PTO Ratio would be
(Engine RPM) x (Engine:PTO Ratio) = 850 rpm x 1.61 = 1369 rpm
Figure 10: Example of PTO Power Flow through a Direct Drive DT12-DA (DH) or DT12-DB (DHL)
For a complete list of programming options for the DT12 Rear PTO, please see the DETROIT™
Transmissions Electronic Application and Installation Manual (DDC-SVC-MAN-0128) via the