User Manual
Page 30 of 39 DETROIT DDC-ENG-MAN-0001
NOTE: It is critical that the edge-molded gasket is used against the PTO Adapter – failure to do so
may result in oil leakage!
Figure 35: Installation of the Muncie PTO to the PTO Adapter and transmission
NOTE: See Muncie PTO Operators Manual, IN84-03, for further PTO Installation details, activation
kit instructions, as well as warranty and maintenance information.
PTO POWER SPLIT
The term PTO Power Split refers to the simultaneous operation of the Rear and Bottom PTO’s. While
operating at the same time, the maximum torque load distribution among the PTO’s has to meet the following
boundary conditions:
Max Continuous Torque = 525 lb-ft
Max Intermittent Torque = 750 lb-ft
The definition of “Intermittent Torque” is as follows:
Maximum torque for 1.5 minutes in a 15-minute cycle.
Figure 36: Torque signal showing intermittent vs Continuous Torque