Specifications

Service Training
Page 4.2
Section 62
09.04
Using adapter V, install LP gauge at port F of power limiter. Start engine and
read pressure with the brake released.
Pressure = 17.5 - 21 bar.
Δp = 5 bar
or more.
Loosen the clamping screw on right (looking in direction of travel) travel control
shaft, bring travel control shaft into noticeable neutral position. Tighten the
clamping screw. Determine Δp between ports YF and ZF.
no
no
no
yes
yes
yes
See "Hydrostatic travel drive".
Δp = 0 - 0,5 bar.
A
B
See "Hydrostatic travel drive".
Install a second LP gauge with adapter V at port E of power limiter. Start the
engine, release the brake and determine Δp between ports E and F.
Install LP gauge with adapter III at ports YF and ZF of power limiter. Start the
engine and determine Δp with the brake released.