Specifications
Service Training
Page 4.2
Section 75
09.04
noyes
noyes
noyes
Install HP gauge to HP modulation with screw coupling 1 .1. Plug port BR on
travel control.
Start engine, release brake pedal. Depress V pedal approx. half way and read
the LP at port F and HP on HP gauge.
R
S
Q
Δp 10 - 11 bar.
Δp now 10 - 11 bar.
Disconnect the line from port X on the power limiter and connect a LP gauge
with screw coupling 1.1 to port X, Determine the Δp between ports F and X with
the F and R pedals fully depressed.
Connect LP gauge with adapter lll to port X at the power limiter and a second
LP gauge to F. Determine the Δp between ports F and X with the F and R pedals
fully depressed.
Fault in power limiter.
Eliminate the fault or
renew it.
Oil leak in the remote
control for hydraulic
motors. Locate and
remedy fault, see "Q
min
of hydraullc motors".
Average wheel
speed of 155 - 165 rpm
obtained to both
sides.
Check maximurn swivel
angle of BPV, see
"Mechanical limitation of
swivelling angle". Check
the minimum swivelling
angle of the HMV, see
"Q
min
of hydraulic motors
HMV 105".