SWITCHGEAR A1
TEST CONDITION
- Ignition coil in order
TESTING
- Pull out plug from TSZ switchgear and press wire fuse.
- Connect voltmeter to the plug between contact 4 (+) and 2 (-).
- Switch ignition on.
Target value: about the same as battery voltage, otherwise determine interruption on the basis of
wiring diagram and remove it.
- Switch ignition off.
- Insert the plug back into the TSZ switchgear.
- Take the plug out of the induction transmitter (ignition distributor).