Specifications
Service Training
Section 4.9
Page 53
12.05
4.9.4.4 ADJUSTMENT OF THE PROPELLANT GAS MIXERS
ASSEMBLY
- Close throttle valve manually.
- Adjust limit stop screw (9) so that with the throttle valve at the limit stop (8) closed, it approaches the
assembly, and then turn back 1 more turn.
- Move lever (7) on shaft and clamp at an angle of 30
+3
°.
- Install mixer.
- Press throttle valve manually onto the limit stop and adjust connecting rod (5) between magnet (1) and
lever (7) to an initial tension of 1 mm and press on ball grip of lever (6).
- Lock rod (5) with nuts (6).
1 Operating magnet
2 Full load mixture adjustment screw
3 Idling mixture adjustment screw
4 Mixer
5 Connecting rod
6 Lock nut
7 Lever
8 Limit stop
9 Limit stop screw