Specifications

Service Training
Page 29
Section 4.1
09.06
- Attach new injection lines with sealing rubber elements.
Tighten cap screws finger-tight.
HINWEIS: When installing the injection lines make sure
that sealing cones are exactly aligned one on
top of the other.
Subsequent bending is not allowed. Injeetion
lines must not be re-used.
- Tighten bolts of claws.
Specified tightening torque: 16
+ 5
Nm
- Pre-tension cap nuts of injection lines on injection pumps
and injection nozzles to a tightening torque of approx.
5 Nm. Then tighten cap nuts.
Specified tightening torque: 25
+3,5
Nm
NOTE: Use claw grip wrench 8018.