Specifications

Service Training
Page 35
Section 4.1
09.06
4.1.2.9 INJECTION PUMP
4.1.2.9.1 ADJUSTING THE BEGIN OF DELIVERY
If an injection pump must be replaced, the begin of delivery must be re-adjusted by determining the shim
thickness anew.
DETERMINING THE SHIM THICKNESS
The old injection pump and shim are not required for this procedure.
Proceed as follows:
In the column marked "EP", read the EP code for cylinder 3 on the name plate on the cylinder head cover,
e.g. 070 (reading sequence: line 1 = cylinder 1, line 2 = cylinder 2, etc.).
Take the corrected injection pump installation dimension (E
K
) in Table 1 according to the EP code,
e.g. 120.875 mm.
Table 1
E
K
EP code E
K
EP code E
K
EP code E
K
EP code
(mm) (mm) (mm) (mm)
119,25 230 119,85 254 120,45 278 121,05 302
119,275 231 119,875 255 120,475 279 121,075 303
119,3 232 119,9 256 120,5 280 121,1 304
119,325 233 119,925 257 120,525 281 121,125 305
119,35 234 119,95 258 120,55 282 121,15 306
119,375 235 119,975 259 120,575 283 121,175 307
119,4 236 120,0 260 120,6 284 121,2 308
119,425 237 120,025 261 120,625 285 121,225 309
119,45 238 120,05 262 120,65 286 121,25 310
119,475 239 120,075 263 120,675 287 121,275 311
119,5 240 120,1 264 120,7 288 121,3 312
119,525 241 120,125 265 120,725 289 121,325 313
119,55 242 120,15 266 120,75 290 121,35 314
119,575 243 120,175 267 120,775 291 121,375 315
119,6 244 120,2 268 120,8 292
119,625 245 120,225 269 120,825 293
119,65 246 120,25 270 120,85 294
119,675 247 120,275 271 120,875 295
119,7 248 120,8 272 120,9 296
119,725 249 120,825 273 120,925 297
119,75 250 120,35 274 120,95 298
119,775 251 120,375 275 120,975 299
119,8 252 120,4 276 121,0 300
119,825 253 120,425 277 121,025 301