- Turn bolts in again by 60° and gradually tighten to a
tightening torque of 7 Nm, 10 Nm and 30 Nm.
NOTE: Start with the outer boit remotest from
flywheel.
- Turn knurled lock bolt back again.
Remove press on device 100 830.
NOTE: Check smooth movement of control rod from
stop position to start position. Actuate cut-off
lever to this end.
- Mount new O-ring.
NOTE: Slightly oil O-ring.
- Press control rod into stop position using the cut-off
lever and retain.
- Install engine shut-off device. Tighten bolts. Plug in
cable connector.
Specified tightening torque: 21 Nm