Specifications

Stop procedure Operation
© 2008 25
3
Shutting off
Avoid switching off from full load (coking/
blockage of the remaining lubricating oil in
the turbocharger bearing housing). The lu-
bricating oil supply of the turbocharger is
then no longer guaranteed! This shortens
the life of the turbocharger.
Run the engine in low idling speed for ap-
proximately one minute after relieving the
load.
The control unit remains active for about
another 40 seconds to save the system
data (lag) and then switches off automati-
cally.
Electrical shutdown (optional)
z
Run engine up to idling speed.
z
Move the key to position 0.
Control lamps A+B+C go out.
A = charge pilot light
B = lube oil pressure pilot light
C = pilot light for pre-heating system
0 = gear position: switch off engine
C
B
A
Shutting off
z
Run engine up to idling speed.
z
Move the key to position 0.
Control lamps A+B+C go out.
z
In case of electrical shutdown or power failure
the shutoff lever (2) is switched off by the lifting
magnet up to engine standstill. The charging
control lamp and lubricating oil pressure control
lamp light up.