User Guide DEVIreg™ 535 Electronic Intelligent Thermostat www.DEVI.
DEVIreg™ 535 Table of Contents 1 Introduction . . . . . . . . . . . . . . . 1.1 Safety Instructions . . . . . . . . 4 5 2 Settings . . . . . . . . . . . . . . . . . 2.1 Increase/Decrease Preferred Temperature . . . . . . . . . . . . . . 2.2 Time and Day of Week . . . . . . 2.3 Periods with Lowering of Temperature . . . . . . . . . . . . . . . . 2.4 Minimum Floor Temperature . . 2.5 Frost Protection . . . . . . . . . 2.6 Safety Lock . . . . . . . . . . . . 2.
DEVIreg™ 535 1 Introduction DEVIreg™ 535 is a electronic timer temperature controller specially designed for floor heating systems. Once set, the thermostat automatically adjusts the heating to meet your comfort levels regardless of changing weather conditions by measuring the floor temperature and combining it with the room temperature. Even the programming of economy temperatures (i.e. lowering of temperature during the night and when you are out of the house) is very simple.
DEVIreg™ 535 1.1 Safety Instructions Please observe the following guidelines: ▪ Do not cover the thermostat, e.g. by hanging towels or similar items in front of it! This will impair the ability of the thermostat to sense and adjust the room temperature correctly. ▪ Do not spill liquids of any kind into the thermostat. ▪ Do not open, disassemble, or tamper with the thermostat in any way. ▪ If the thermostat is installed in a place frequented by small children, use the safety lock.
DEVIreg™ 535 2 Settings Using clear visual symbols, the display of the thermostat shows active and selected functions, the actual temperature and the time: 1. 2. 3. 4. 5. 6. 7. 8. 9.
DEVIreg™ 535 2.1 Increase/Decrease Preferred Temperature How to increase or decrease the temperature 1. Press the arrow buttons ▲▼ to either increase or decrease the temperature. The temperature is changed in increments of 0.1°C. 2. Press the • button to accept. Note: If the thermostat is configured to use a floor sensor only, and you try to increase the temperature above the maximum floor temperature limit, the corresponding symbol will flash on the display. 2.
DEVIreg™ 535 2. Press the • button and the hours start flashing. Use the arrow buttons ▲▼ to select the hour. 3. Press the • button and the minutes start flashing. Use the arrow buttons ▲▼ to select the minutes. 4. Press the • button and the day of week start flashing. Use the arrow buttons ▲▼ to select the day of week. The seven top bars indicate Monday through Sunday. 5. Press the • button to accept. 2.
DEVIreg™ 535 The day is divided into 4 time periods (see image): morning , day , evening and night . The start time of each period can be configured.
DEVIreg™ 535 Default timer settings By default, the timer has the following settings: Floor sensor only Room sensor only Floor and Room sensor Temperature: Comfort 25 °C 21 °C 21 °C Economy 5 °C 17 °C 17 °C Periods – Day rhythm: Morning 06:00-08:00 Day 08:00-16:00 Evening 16:00-22:30 Night 22:30-06:00 You can use these settings as they are, or you can change them to match your day pattern. Return to Default Timer Settings 1. Turn off the thermostat. 2.
DEVIreg™ 535 Timer Programs Four different programs can be selected. Program 1 Manual mode. A constant temperature is maintained 24 hours all week. Program 2 The temperature is lowered to economy temperature during the day and night period all week. P2 is a day program for e.g. working days where the temperature is decreased during the middle of the day and at night. In the morning and evening, comfort temperature is preferred.
DEVIreg™ 535 By default, program 1 is selected. How to define comfort periods and economy periods Note: When defining the starting time of the 4 periods keep in mind that the thermostat will start heating/stop heating at the given time. Therefore some periods should start and end before, to compensate for the time it takes to heat up or cool down. 1. Press the clock pinhole with a small screw driver, pencil, or needle. The display now changes from temperature to time display. 2.
DEVIreg™ 535 4. Use ▲▼ to change the start time of this period (in increments of 15 minutes) and press • to accept . 5. Repeat Step 4 to define the start time of the day, evening and night periods. Note: When setting the time periods you cannot go back to the previous time period until the last one is set. This is to ensure that the periods do not overlap. 6. Press • again and the preset comfort temperature starts flashing. 7. Use ▲▼ to change it and press • to accept . 8.
DEVIreg™ 535 2.4 Minimum Floor Temperature Note: Minimum floor temperature only applies if the thermostat is configured to use a combination of room and floor sensor. This setting will overrule any other set point as you always want e.g. 20°C at the floor sensor How to set the minimum floor temperature 1. Press the clock pinhole with a small screw driver, pencil, or needle to access thermostat settings. The display now changes from temperature to time display. 2.
DEVIreg™ 535 4. Press the • button to accept. The floor temperature is now kept above the specified lower limit. 2.5 Frost Protection How to set the thermostat in frost protection mode 1. Hold down ▼ until you reach the lowest setting, then press ▼ again. A frost symbol now appears and the temperature display flashes. 2. To accept, press • or leave it flashing for 10 seconds. How to turn off frost protection mode 1. Press ▲ (0.5sec).
DEVIreg™ 535 2.6 Safety Lock The safety lock is used for preventing undesirable changes to the thermostat settings, i.e. all buttons will be locked until the safety lock is turned off again. How to turn the safety lock on and off 1. Press the lock pinhole with a small screw driver, pencil, or needle. If the safety lock was turned off, it will now be turned on and vice versa. When turned on, a lock symbol appears on the thermostat display. 2.
DEVIreg™ 535 How to display the floor temperature Note: This option only applies if the thermostat is configured to use a combination of room and floor sensor. 1. Pressing ▲ and ▼ at the same time for 2 seconds. The floor sensor symbol now appears, and the floor sensor temperature will be displayed for 2 minutes. 2.8 Turning the Thermostat On and Off How to turn the thermostat off 1. Hold down ▼ until you reach 5.0°. Then press ▼ again twice. OFF appears on the display. 2. Press • to accept.
DEVIreg™ 535 3 Error Messages Light Indications (LED) No light The system is turned off. Green light System is standing by, set point temperature reached Green light flashing Floor sensor is defect Red light System is heating Switching between red and green light The floor temperature limit prevents the set point room temperature from being reached.
DEVIreg™ 535 Error code Problem Solution Clock Time settings symbol were lost due flashing to power cut. in display The thermostat resumes to manual mode. E4 symbol flashing in display Let the thermostat cool for period. Then switch the thermostat off and on. If the error persists contact your authorized installer. The thermostat has overheated and has switched off. E5 sym- Floor sensor bol short circuitflashing ed. in display If the error persists contact your authorized installer.
DEVIreg™ 535 4 Warranty 2 YEAR 5 20 Disposal Instruction User Guide
DEVIreg™ 535 User Guide 21
DEVIreg™ 535 22 User Guide
DEVIreg™ 535 User Guide 23
DEVIreg™ 535 Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: EH@DEVI.com www.DEVI.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.