Specifications
PARTS REPLACEMENT/MAINTENANCE
CHART 1 – AIR CAPS
PART NO. FOR
AIR CAP
TECHNOLOGY
MARKING ON
AIR CAP
RECOMMENDED
INLET PRESSURE
AIR FLOW
(L/min)
COMM-100-HS1 HVLP HS1 29.0 psi (2.0 bar) 135
COMM-100-TS1 TRANS-TECH
®
TS1 29.0 psi (2.0 bar) 100
COMM-100-RS1 TRANS-TECH
®
RS1 14.0 psi (1.0 bar) 55
NOTE: When removing air cap from retaining ring, don’t remove the Slip Ring (2) or Retaining Ring Seal (5) from the
Retaining Ring. Damage to the parts may occur. Slip ring and Retaining Ring seal are not available as replacements.
Simply wipe parts clean and reassemble with new or clean air cap.
CHART 2 – FLUID NOZZLE RANGE & FLUID NEEDLE
PART NO. ON FLUID NOZZLE PART NO. NEEDLE
COMM-200-08
COMM-300-0810
COMM-200-10
COMM-200-12
COMM-300-1214
COMM-200-14
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time. Torque to 70 in-lbs (8 Nm).
Don’t over tighten the fluid nozzle. Use 6mm Spanner supplied with the gun and check with a torque wrench.
Page 13
SB-2-858-B