regulations.
/_ WARNING : Aftercooler, pump head,
and surrounding parts are very hot. Do not
touch (see Hot Surfaces on page 4).
1. Ensure that the unit is off.
2. Allow the unit to cool.
3. Place a suitable container under the
drain plug (K).
4. Remove the oil dipstick (L) from crank-
case.
5. Remove the oil drain plug.
6. Allow ample time for all the oil to drain out. (Tilting the compressor
towards the drain plug assists draining.)
7. Reinstall the oil drain plug.
8. Fill the pump with DEWALT synthetic compressor oil (See
Specifications).
9. Reinstall the oil dipstick.
Accessories
Recommended accessories for use with your tool are available for
purchase from your local dealer or authorized service center. If you
need assistance in locating any accessory for your tool, contact:
DEWALT Industrial Tool Co., 701 East Joppa Road, Baltimore,MD
21286 or call 1-800-4-DEWALT.
/_ CAUTION: The use of any other accessory not recommended
for use with this tool could be hazardous.
SERVICE
Please have the following information available for all service calls:
Model Number
Serial Number
Date and Place of Purchase
Repairs
To assure product SAFETY and RELIABILITY, repairs, maintenance
and adjustment should be performed by authorized service centers
or other qualified service organizations, always using identical
replacement parts.
Full One Year Warranty
DEWALT heavy duty industrial tools are warranted for one year from
date of purchase. We wilt repair, without charge, any defects due to
faulty materials or workmanship. For warranty repair information, call
1-800-4-DEWALT. This warranty does not apply to accessories or
damage caused where repairs have been made or attempted by
others. This warranty gives you specific legal rights and you may
have other rights which vary in certain states or provinces.
FREE WARNING LABEL REPLACEMENT: If your warning labels
become illegible or are missing, call 1-800-4-DEWALT for a free
replacement.