CAUTION: Risk of unsafe operation. Do not operate in vertical
position.Verticalpositionisforstorageonly.
CAUTION: Risk of unsafe operation. Compressed air from the unit
may contain wa ter condensation and oil mist. Do not spray un fil-
tered air at an item that could be damaged by moisture. Some air
op er ated tools or de vic es may require filtered air. Read the in struc-
tions for the air tool or device
1. Follow Pre-Start Checklist under Preparation for Use.
2. Move the Auto/Off switch to the AUTO(–) position.
3. Select Stop Start Mode or Constant Run Mode. See Dual
Control under Features for description:
STOP START MODE
a. Turn knob on top of pilot valve (M) clockwise until fully
closed.
WARNING:Riskofpropertydamage.OvertighteningthePilotValve
knob can cause damage to the pilot valve.
b. Allow compressor to reach cut-out pressure. If compressor
does not stop, contact a D
e
WALT service center or call
1-800-4-D
e
WALT (1-800-433-9258) for assistance.
CONSTANT RUN MODE
a. Turn knob on top of pilot valve (M) fully counterclockwise until
fully open.
WARNING: Risk of property damage. Over loosening the pilot valve
knob can cause damage to the pilot valve.
b. The compressor is now in constant run mode. NOTE: After the
compressor reaches blow-off pressure the unit will continue
to run but will not build additional tank pressure until the air is
used and the pilot valve reset pressure is reached. A slight air
noise may be heard while the air is being unloaded through
the pump head. If compressor shuts off, contact a D
e
WALT
service center or call 1-800-4-D
e
WALT (1-800-433-9258) for
assistance.
NOTE: For proper operation the pilot valve blow-off pressure must be
below the pressure switch cut out pressure.
4.Adjust regulator (F) to desired setting. See Regulator under
Features.

1. Move Auto/Off switch (L) to the OFF(O) position. NOTE: If
finished using compressor, follow Steps 2–6. NOTE: If operating in
the constant run mode turn pilot valve knob clockwise until it stops
before moving the Auto/Off switch (L) to the OFF(O) position.
2. Pull the regulator knob (F) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push knob
in to lock in place.
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank,
see Draining Air Tank under Maintenance
.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.

The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure Auto/Off (L) switch is in the OFF(O) position.
2. Remove air compressor plug from outlet.