Use and Care Manual
ENGLISH
6
Your
DeWALT
pin nailer includes an integrated belt
hook
7
and can be attached to either side of the tool to
accommodate left- or right-handed users.
If the belt hook is not desired at all, it can be removed from
thetool.
Removing and Reattaching the Belt Hook
1. Disconnect the air supply from tool.
2. To switch the tool from right- to left-hand usage simply
remove the screw
12
from the opposite side of the tool
and reattach the belt hook
7
on the other side.
Fig. J
7
12
MAINTENANCE
Tool-Free Jam Release (Fig. A, B, D, K)
WARNING: Always disconnect air supply before
clearing a jammedpin.
Your pin nailer features a tool-free jam release for clearing
jammedpins.
To Clear a Jammed Pin
1. Disconnect the air supply from thetool.
2. Depress the magazine release lever
5
and pull the
magazine
6
back to stop pinfeeding.
3. Remove the no-mar tip
9
.
4. Grab the small tabs on each side of the nose cover
8
and pull up as shown in FigureB.
5. With the nose cover lifted, slide the inner nose cover
13
forward and lift up to clear the jammedpin.
Fig. K
13
6. Push the pinch lever
11
down to lock the mechanism
back to operating position after the jam is cleared as
shown in FigureD.
7. Attach the no-martip.
8. Close the magazine and reconnect the airsupply.
Tool Operation Check (Fig. A)
WARNING: Remove all fasteners from tool before
performing tool operationcheck.
Trigger Operation with a Secondary
Trigger
The primary trigger
2
is located uder the trigger valve. It
can actuate the tool only if the secondary trigger
3
has
already been pulled.
The secondary trigger is located under the handle. The
secondary trigger prevents the primary trigger from
actuating the tool if the secondary trigger has not been
pulledfirst.
Place the nose of the tool against a work piece for all of the
following operationchecks.
1. With hand on rear end of the handle, further back away
from the secondary trigger, and not squeezing the
secondary trigger, use finger to pull the primarytrigger.
THE TOOL MUST NOTCYCLE.
2. With hand on handle, and squeezing the secondary
trigger, use finger to pull the primarytrigger.
THE TOOL MUSTCYCLE.
CAUTION: While the secondary trigger remains
squeezed, the tool will cycle each time the
primary trigger ispulled.
Accessories
WARNING: Since accessories, other than those
offered by
DeWALT
have not been tested with this
product, use of such accessories with this tool could be
hazardous. To reduce the risk of injury, only
DeWALT
recommended accessories should be used with
thisproduct.
Recommended accessories for use with your tool are
available at extra cost from your local dealer or authorized
service center. If you need assistance in locating any
accessory, please contact
DeWALT
, call 1-800-4-
DeWALT
(1-800-433-9258).
Cleaning
WARNING: Blow dirt and dust out of all air vents with
clean, dry air at least once a week. To minimize the risk
of eye injury, always wear ANSI Z87.1 approved eye
protection when performingthis.
WARNING: Never use solvents or other harsh
chemicals for cleaning the non‑metallic parts of
the tool. These chemicals may weaken the plastic
materials used in these parts. Use a cloth dampened
only with water and mild soap. Never let any liquid
get inside the tool; never immerse any part of the tool
into aliquid.
Repairs
WARNING: To assure product SAFETY and
RELIABILITY, repairs, maintenance and adjustment
should be performed by a
DeWALT
factory service
center or a
DeWALT
authorized service center. Always
use identical replacementparts.