User Manual

ENGLISH
5
WARNING: To reduce the risk of injury, read the
instructionmanual.
Definitions: Safety Guidelines
The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to
thesesymbols.
DANGER: Indicates an imminently hazardous
situation which, if not avoided, will result in death or
seriousinjury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or
seriousinjury.
CAUTION: Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderateinjury.
NOTICE: Indicates a practice not related to
personal injury which, if not avoided, may result in
propertydamage.
Denotes risk of electricshock.
Denotes risk offire.
The vibration and/or noise emission level given in this
information sheet has been measured in accordance with
a standardised test given in EN60745 and may be used to
compare one tool with another. It may be used for a preliminary
assessment ofexposure.
WARNING: The declared vibration and/or noise emission
level represents the main applications of the tool. However
if the tool is used for different applications, with different
accessories or poorly maintained, the vibration and/or
noise emission may differ. This may significantly increase
the exposure level over the total workingperiod.
An estimation of the level of exposure to vibration and/or
noise should also take into account the times when the tool
is switched off or when it is running but not actually doing
the job. This may significantly reduce the exposure level
over the total workingperiod.
Identify additional safety measures to protect the operator
from the effects of vibration and/or noise such as: maintain
the tool and the accessories, keep the hands warm
(relevant for vibration), organisation of workpatterns.
DCW600 DCW604
Voltage V
DC
18 18
Type 1 1
Battery type Li-Ion Li-Ion
Power output W 930 930
No-load speed rpm 16000–
25500
16000–
25500
Router carriage 1 column 2 columns
Router carriage stroke mm 55 55
Collet Size mm 8 8
Cutter Diameter, max 30 30
Weight (without battery pack) kg 1.54 2.40
Noise and/or vibration values (triax vector sum) according to EN60745-2-17:
L
PA
(emission sound pressure level) dB(A) 73 73
L
WA
(sound power level) dB(A) 84 84
K (uncertainty for the given sound
level)
dB(A) 3 3
Vibration emission value a
h
= m/s
2
4.7 4.7
Uncertainty K = m/s
2
2.7 2.7
EC-Declaration of Conformity
Machinery Directive
Plunge Router
DCW600, DCW604
DeWALT
declares that these products described under
Technical Data are in compliance with:
2006/42/EC, EN60745-1:2009 +A11:2010, EN60745-2-17:2010.
These products also comply with Directive 2014/30/EU and
2011/65/EU. For more information, please contact
DeWALT
at
the following address or refer to the back of themanual.
The undersigned is responsible for compilation of the technical
file and makes this declaration on behalf of
DeWALT
.
Markus Rompel
Vice-President Engineering, PTE-Europe
DeWALT
, Richard-Klinger-Straße 11,
D-65510, Idstein, Germany
15.03.2019
English (original instructions)
Congratulations!
You have chosen a
DeWALT
tool. Years of experience, thorough
product development and innovation make
DeWALT
one of the
most reliable partners for professional power toolusers.
Technical Data
PLUNGE ROUTER
DCW600, DCW604