Chronic Toxicity
Chronic Toxicity
Chronic exposure to corrosive fumes/gases may cause erosion of the teeth followed by jaw
necrosis. Bronchial irritation with chronic cough and frequent attacks of pneumonia are
common. Gastrointestinal disturbances may also be seen. Lead compounds may be
absorbed by ingestion, by inhalation and through the skin. Lead may damage kidney function,
the blood forming system and the reproductive system. Avoid repeated exposure. Possible
risks of irreversible effects. May cause adverse effects on the bone marrow and blood-forming
system. Contains a known or suspected reproductive toxin.
Carcinogenicity
The table below indicates whether each agency has listed any ingredient as a carcinogen.
ACGIH: (American Conference of Governmental Industrial Hygienists)
A2 - Suspected Human Carcinogen
A3 - Animal Carcinogen
IARC: (International Agency for Research on Cancer)
Group 1 - Carcinogenic to Humans
Group 2A - Probably Carcinogenic to Humans
Group 3 - Not Classifiable as to Carcinogenicity in Humans
NTP: (National Toxicity Program)
Known - Known Carcinogen
Reasonably Anticipated - Reasonably Anticipated to be a Human Carcinogen
OSHA: (Occupational Safety & Health Administration)
X - Present
Reproductive Toxicity
Product is or contains a chemical which is a known or suspected reproductive hazard.
Developmental Toxicity
Contains ingredients that have suspected developmental hazards
Target Organ Effects
Blood. Reproductive system. Damage to fetus possible Central nervous system (CNS). Eyes.
Gastrointestinal tract (GI). Gingival Tissue. Kidney. Respiratory system. Skin. Teeth.
12. ECOLOGICAL INFORMATION
Ecotoxicity
Harmful to aquatic organisms.
13. DISPOSAL CONSIDERATIONS
Waste Disposal Methods
This material, as supplied, is a hazardous waste according to federal regulations (40 CFR
261). Should not be released into the environment.
Contaminated Packaging
Do not re-use empty containers.
US EPA Waste Number
D002
D008
California Hazardous Waste Codes
792
This product contains one or more substances that are listed with the State of California as a hazardous waste.