CODE POSSIBLE CAUSE POSSIBLE SOLUTION
24
Damaged regulator Replace
25
Regulator open Roate the regulator knob counter-clockwise to its built-in stop.
26
Low voltage/motor overload Check that power supply is adequate and that compressor is
on a dedicated circuit. If using extension cord, try using without.
If compressor is connected to a circut protected by a fuse, use
dual element time delay fuses (Buss Fusetron type “T” only).
27
Restricted air passages Inspect and replace transfer tubes or check valve, as
required.
28
Low voltage motor Furnish adequate powder.
29
Bad check valve Replace check valve.
30
Seized pump Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
31
Oil level too high Reduce to proper level. See Compressor Pump Oil under
Maintenance.
32
Poor ventilation Relocate compressor to an area with cool, dry, well circulated
air, at least 12 in. from nearest wall.
33
Dirty cooling surfaces Clean all cooling surfaces thoroughly.
34
Too much back pressure in tank. Open drain valve when starting motor.
35
Compressor too cold Move compressor to a warmer location.