How to Guide

3
English
CONTENTS
WARNINGS 2
HEATER SPECIFICATIONS 3
OPERATING & SAFETY PRECAUTIONS 4
LIGHTING/OPERATING INSTRUCTIONS 5
MAINTENANCE 5
EXPLODED VIEW AND PARTS LIST 8
WIRING DIAGRAM 11
Model DXH80KTHC DXH140KTHC DXH210KTHCX
Burn Rate 80,000 BTU/hr (23.4 kW) 140,000 BTU/hr (41.2 kW) 210,000 BTU/hr (61.5 kW)
Fuel Rate .59 gal/hr (3.9 L/hr) 1.0 gal/hr (3.9 L/hr) 1.6 gal/hr (6.0 L/hr)
Electrical Input
115 V, 60 HZ, 1 Ø, 4.0 A 115 V, 60 HZ, 1 Ø, 5.5 A 115 V, 60 HZ, 1 Ø, 5.5 A
Line Protection 10 A 10 A 10 A
Min. operating voltage
110 V 110 V 110 V
Pressure Setting 4.2 psig (29 kPa) 6.8 psig (47 kPa) 8.4 psig (58 kPa)
Max. Outlet Temp. 1300 °F (704 °C) 1300 °F (704 °C) 1300 °F (704 °C)
Fuel Tank Capacity 6 gallons (22.7 L) 10 gallons (37.9 L) 15 gallons (56.8 L)
Ignition Direct Spark, Continuous Direct Spark, Continuous Direct Spark, Continuous
Spark Generator Igniter, 12 kV, 0.36 A Igniter, 12 kV, 0.36 A Igniter, 12 kV, 0.36 A
Primary Safety Control Solid State Control Solid State Control Solid State Control
Certication
Heater Specications
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- Service must be performed by a qualified service agency.
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
Minimum Clearances:
Outlet: 8 feet (250 cm) / Sides, Top, Rear: 3 feet (91.4 cm)