Operating instructions
ATTENTION!
WARNING!
Service hotline
In the case of technical problems, contact our Service hotline. Switzerland: 
Tel. 0900 00 1675 (national charges, Swisscom at time of going to print: 
CHF2.60/min).Inthecaseofclaimsunderthetermsofguarantee,contact
your sales outlet.
Maintenance
Cleanthesurfaceofthehousingwithasoft,uff-freecloth.Donotuseany
cleaning agents or solvents.
Guarantee
Dexford equipment is produced and tested according to the latest produc-
tion methods. The implementation of carefully chosen materials and highly 
developed technologies ensure trouble-free functioning and a long service 
life. The terms of guarantee do not apply to the batteries or power packs 
usedintheproducts.Theperiodofguaranteeis24monthsfromthedate
ofpurchase.Alldecienciesrelatedtomaterialormanufacturingerrors
within the period of guarantee will be redressed free of charge. Rights to 
claims under the terms of guarantee are annulled following tampering by 
the purchaser or third parties. Damage caused as the result of improper 
handling or operation, normal wear and tear, incorrect positioning or 
storage, improper connection or installation or Acts of God and other 
externalinuencesareexcludedfromthetermsofguarantee.Inthecase
of complaints, we reserve the right to repair defective parts, replace them 
or replace the entire device. Replaced parts or devices become our pro-
perty. Rights to compensation in the case of damage are excluded where 
there is no evidence of intent or gross negligence by the manufacturer. If 
your device does show signs of a defect within the period of guarantee, 
please contact the sales outlet where you purchased the Dexford device, 
producing the purchase receipt as evidence. All claims under the terms 
of guarantee in accordance with this agreement can only be asserted at 
the sales outlet. No claims under the terms of guarantee can be asserted 
after a period of two years from the date of purchase and hand-over of the 
product.
Disposal
In order to dispose of your device, take it to a collection point 
provided by your local public waste authorities (e.g. recycling 
centre). According to the laws on the disposal of electronic and 
electrical devices, owners are obliged to dispose of old electronic 
and electrical devices in a separate waste container. The adjacent 
symbol indicates that the device must not be disposed of in normal 
domestic waste!
You are legally obliged to dispose of power packs and batteries 
at the point of sale or in the corresponding containers provided at 
collection points by local public waste authorities. Disposal is free of 
charge. The symbols indicate that the batteries must not be disposed 
of in normal domestic waste and that they must be brought to collection 
points provided by local public waste authorities. Packaging materials must 
be disposed of according to local regulations.
Declaration of Conformity
ThisdevicefullstherequirementsstipulatedintheDirective
1999/5/EConradioequipmentandtelecommunicationsterminal
equipmentandthemutualrecognitionoftheirconformity.Conformi-
tywiththeabovementioneddirectiveisconrmedbytheCEmarkonthe
device.ToviewthecompleteDeclarationofConformity,pleaserefertothe
free download available on our web site www.dexford.com.
ENGLISH
WSRC 2254
Weather Station with wireless-thermometer
and radio clock
Operating Instructions
    Please read and observe the following information and keep the   
    operating manual nearby for future reference!
Thermo-hygro sensor (WRS)
Safety information
 Only use batteries of the same type!
 Always treat batteries with due care and attention and only use 
  batteries as described.
 Never use standard and rechargeable batteries together. Never use   
  rechargeable batteries or standard batteries with different capacities or 
  charge statuses together. Never use standard or rechargeable batteries 
  which are damaged.
  Risk of suffocation through small objects, packaging and protective foil!
 Keep children away from the product and its packaging!
  Risks to health and the environment from batteries!
 Never open, damage or swallow batteries or allow them to pollute the   
  environment. They could contain toxic and ecologically harmful heavy  
  metals.
Preventexposuretoenvironmentalinuences,e.g.smoke,dust,
  vibration, chemicals, moisture, heat and direct sunlight.
Onlyallowrepairstobecompletedbyqualiedpersonnel.
Package contents
Weather station main unit, Thermo-hygro sensor, Operating manual
Display icons and operating elements
  1  Weather Forecast
 2 Outdoorhumiditytrend, 
  3  Outdoor humidity 
 4 Indoorhumidity
 5 MoonPhase
  6  Alarm 
  7  Time 
  8  Day of week
 9 RCCsymbol(radioclock),„S“=summertime(+1hour)
10 Month
 11  Date 
12 Livingspacehumidity(Comfortable,dry,humid)
 13  Indoor temperature 
14 RFsymbolandChannel
 15  Indoor temperature trend, 
 16  Outdoor temperature 
 17  Outdoor temperature
 18  Outdoor humidity
 19  Battery compartment (Back side)
 A MODE
 B ALARM
C +
 D CHANNEL(Resetoutdoortemperaturememoriespress3sec.)
  E  - 
 F SNOOZE/LIGHT
 a Changefrom°C/°F
 b Changechannel
STARTING UP
  After inserting the batteries, the main unit will connect with the radio   
 transmitter(WRS)byRFsignal.TheRFsignal(14)symbolattheout 
 areawillash.
  This process takes about 3 minutes. Then the display shows the   
  outdoor temperature and humidity. In case of failure of reception, pls   
 press“CHANNEL“(D)formorethan3secondstoreceiveagain.
  The weather station is capable of receiving up to 3 different channels.  
 Selectthechannelnumber(1,2,or3)bypressingthe“b”switch.
  The weather station will scan the 3 channels automatically.
 Selectthechannelnumber(1,2,or3)bypressingthe“Channel”button
  (D) on weather station.
 TheautomaticreceivingoftheDCFradiosignal(DCF77,Timesignal 
  frequency 77,5 kHz) begins after 3 minutes of outdoor RF reception. 
 ThisDCFreceptionprocessisgoingon,theashingsymbol“radio 
  tower“ (9) appears in the time display area at the same time.
  ATTENTION: Please note all other clock / weather station settings  
  seize to function when the clock is in RCC synchronization mode.
  Once radio signal receiving is successful, the display shows the symbol 
 “radiotower“(9)continuously.Noashing.Onesynchronisationper 
 dayissufcienttokeepthetimedisplayaccuracyat1second.
 Pleaseobserveaminimaldistanceof2.5mtosourcesofinterference 
  such as televisions or computer screens.
MANUAL SET-UP
(The clock automatically changes from set-up mode to time display mode if 
no keys are pressed for 8 seconds.)
 Press and hold key “MODE“ for 3 seconds. 
 Thedisplayforthetimezoneisashing.
 Use “+“ and “-“ to select
 Press “MODE“toconrm.
 Thedisplayforthehourisashing
 Use “+“ and “-“ to select
 Press “MODE“toconrm.
 Thedisplayfortheminutesisashing
 Use “+“ and “-“ to select
 Press “MODE“toconrm.
 Thedisplayfortheyearisashing.
 Use “+“ and “-“ to select
 Press “MODE“toconrm.
 Thedisplayforthemonthisashing.
 Use “+“ and “-“ to select
17
18
a
b
 Press “MODE“toconrm.
 Thedisplayforthedateisashing.
 Use “+“ and “-“ to select
 Press “MODE“toconrm.
 Thelanguageselectionforthedisplayoftheweekdaysisashing.
  GE = German; EN = English; IT = Italian; FR = French; NE = Dutch;
  ES = Spanish; DA = Danish
 Use “+“ and “-“ to select
 Press “MODE“toconrm.
Alarm set-up
 Press and hold the key “ALARM“ for 3 seconds
 Thehourdisplayofthealarmtimeisashing.
 Use “+“ and “-“ to select
 Press “ALARM“toconrm.
 Theminutedisplayofthealarmtimeisashing.
 Use “+“ and “-“ to select
 Press “ALARM“toconrm.
Alarm on/off
 Press “ALARM”toactivatethealarm
Thealarmsoundsfor2minutesifnokeyispressedtostopit.Otherwise,
thealarmchangesautomaticallyafter2minutesintothe”Snooze“function
Snooze function
 Press the key “SNOOZE/LIGHT“, while the alarm sounds, to activate  
  the snooze function. If the snooze function is activated, alarm symbol is 
 ashing.Thealarmrepeatafter5minutes.
The snooze function can be stopped by pressing any key.
Illumination
 Press the key “SNOOZE/LIGHT“ to activate the display illumination for 
  8 seconds.
Switch between °C / °F
 Press the key “-“ 
WEATHER FORECAST
Sunny  Slightly Cloudy  Cloudy    Rainy
Theweatherstationanalyzestheweatherpatternsfromthepast24hours
todeterminetheforecastforthenext12–24hoursforanareawithinara-
dius of approximately 30-50 km. The weather forecast is only for reference 
and domestic use. Accuracy rate might be lower in extreme conditions.
Moon phase display
The weather station uses saved data to determine the moon phases. So it 
is not necessary to manually enter data. There are 8 moon phases appear.
Feature Value
WSRC2254
W x H x D 70x160x32mm
Weight 178 g (without battery)
Signal frequency 433MHz
Power 2x1,5VAA,notincluded
Temperature range -20~+50°C
Humidity range 20~95%
Thermo-hygro sensor (WRS) max. 30 meters in open area
W x H x D 60x100x25mm
Weight 52g(withoutbattery)
Power 2x1,5VAAA,notincluded
Temperature range -20~+60°C
Humidity range 20~95%
Technical data (All rights reserved)
The radio signal sender (DCF) coverage up to 1500km distance to 
Frankfurt/Main. If, due to bad reception,or no RCC automatic time 
reception is possible, follow the steps below manually.
ATTENTION: Please note all other clock / weather station settings   
seize to function when the clock is in RCC synchronization mode.
The most important is to quit the receiption of radio controlled sig-
nal by holding “-” for 3 seconds in case of the “radio tower”symbol 
ashing before set-up.
1
16
15
12
14
13
8
10
11
9
A
B
D
C
F 19
E
2
3
4
5
6
7




