Operator`s manual

OPERATING INSTRUCTIONS
1. Load clothes into either the upper or lower drum (or both). Close the door(s) completely.
2. Deposit coin or coins equal to or greater than the displayed vend price. Upon deposit of the first coin, the green
light will flash on and off. This light will continue to flash, while additional money may be deposited, until either
the upper drum or lower drum is selected.
3. Select drying temperature by pressing the appropriate switch for the drum to be used. This will put out the green
flashing light, turn on the red light showing the selected temperature and display the amount of time purchased.
4. Press start switch to start drum.
ON RUNNING DRYER
-Opening the door will stop the drum. The drum will restart, if time has not expired, upon closing the door and
pressing the start switch.
-Selected temperature may be changed at any time.
-Running time may be extended by depositing money and pressing the temperature or start switch for the correct
drum. Unless time has expired, the controller will accept coins whether or not the original vend price is equaled.
If time has run out the dryer must be restarted as it was at the beginning of drying the load which requires meeting
or exceeding the vend price.
CHANGING PROGRAMMED DATA
All operating parameters (vend price, temperature, cool-down times) are adjustable. Hours run and money count
information can be displayed and these registers are resettable to zero. There are seventeen programming steps.
These seventeen steps are:
PROGRAMMING ORIGINAL
STEP DESCRIPTION RANGE INCREMENTS SETTING
00 Lower Drum Hour Meter 0-9999 Hours ---- 0
01 Upper Drum Hour Meter 0-9999 Hours ---- 0
02 Left Coin Audit 0-9999 Coins ---- 0
03 Right Coin Audit 0-9999 Coins ---- 0
04 Hot Dry Temperature (Regular) 150-190°F/63-87°C5°F/3°C 175°F/78°C
05 Medium Dry Temperature (Permanent Press) 120-170°F/45-75°C5°F/3°C 150°F/63°C
06 Warm Dry Temperature (Delicates) 110-150°F/39-63°C5°F/3°C 125°F/48°C
07 Left Coin Value 0-9999 cents 1¢ 10¢
08 Right Coin Value 0-9999 cents 1¢ 25¢
09 Vend Price 0-9999 cents 1¢ 25¢
10 Time Per Coin 0-99:55 Min:Sec 5 sec 3:20
11 Time Per Right Coin 0-99:55 Min Sec 5 sec 8:00
12 Free Vend Time 0-99:55 Min:Sec 5 Sec 8:00
13 Hot Dry Cool Down Time 0-10:00 Min:Sec 5 Sec 2:00
14 Medium Dry Cool Down Time 0-10:00 Min:Sec 5 Sec 2:00
15 Warm Dry Cool Down Time 0-10:00 Min:Sec 5 Sec 2:00
16 Temperature Scale °F - °C °F
17 Decimal Point Display OFF or ON -------- ON
18 Seconds on Display OFF or ON -------- OFF
9