Operating instructions
RAPID ADVANCE MODE 
To enter the Rapid Advance mode, turn the key counter-clockwise (CCW). The Rapid Advance 
setting is not marked next to the key, but turning the key CCW until it stops selects this mode. 
The Rapid Advance mode can be entered from either the Idle mode or during the cycle. If the 
cycle has not yet started, press the “START” button. To rapid advance to the next step in the 
wash cycle, push both the “UP” and “START” buttons at the same time. The display will show 
an “Ad” (advance) in the display. The washer will advance to the next bath segment. The water 
will drain before the advance will occur and the time displayed may not be accurate. 
Notes: 
  The indicator lights will show to which segment the cycle has been advanced. 
  The cycle will continue in rapid advance mode even if the key is turned to “RUN” and/or 
removed. 
  Rapid advance cannot skip the final 1-minute tumble of the cycle, and the door lock may 
remain activated for a couple minutes after the cycle has been completed. 
  The chemical injection signals will not operate in Rapid Advance mode. 
To end the cycle and exit the Rapid Advance mode without waiting for the time to count down, 
push and hold the STOP button for 5 seconds or more. 
INJECTION SOURCE DETAILS 
The washer control may be programmed to send output signals for a chemical injection system. 
There is a separate terminal block for connection of the external injection signals. For the 
injection sources, program codes 0 through 6 are as shown in the table below. See the 
ELECTRICAL section for more information. 
Dexter 
Recommended 
Connections 
Controller 
Programmed 
Signals 
Injection 
Terminal Block 
Circuits 
Detergent 
1 
A 
Bleach 
2 
B 
Starch 
3 
C 
Sour/Softener 
4 
D 
5 
A and B 
6 
C and D 
0 
None 