Installation Guide

Rubix Linear Installation (Linear Tile Applications)
DIL-0280-0001 Revision - F 26/01/2023
220-240V / 50-60Hz
IP20
1.
2.
3.
4.
Fitting to go inside a SAS 330 Ceiling Grid
Electrical connection is made via integrated
connection back-flap – allows for LEN L1 (emergency)
WARNING: Luminaire must be earthed. Risk of electric shock from LED boards if operated with cover
removed. Installation / operation outside of luminaires intended scope invalidates warranty. Suitable
only for domestic / light industrial / industrial applications within the scope of EN55015. Tested to
compliance with BSEN 60598: specification for general requirements and tests. Must be installed by a
suitably qualified person in accordance with all relevant legislation. Ambient operating temperature of
0°C to 25°C. If maximum operating temperature is exceeded luminaire will automatically dim / switch
off. Terminal blocks are rated to 16A unless stated otherwise. The light source contained in this luminaire
shall only be replaced by the manufacturer or his service agent or a similar qualified person.
LUMINAIRES WITH EMERGENCY PACK: When supply is isolated battery output terminals may be
live if battery is connected. Isolate mains and battery before servicing. Emergency luminaires require
unswitched live connection taken from same phase as switched supply. When unswitched supply is
connected status indicator illuminates green, when unswitched supply is disconnected indicator
extinguishes and luminaire operates in emergency mode. 24 hour charge period required before
undertaking full discharge test. Emergency test sheets provided should be used to record all emergency
tests. Batteries should be replaced when 3 hour duration is not met. Excessive switching of permanent
live may result in premature battery failure. Battery electrolyte can be harmful to eyes / open wounds,
do not puncture, if electrolyte touches skin / eyes flush with water. Do not incinerate batteries.
Terminal Labelling:
Power
L1 Switched Live
E Earth
N Neutral
Emergency
L2 Unswitched Live
DA/AT3 DALI Autotest
DA/AT3 DALI Autotest
Dimming
-/D1/DA Analogue/DSI/DALI
+/D2/DA Analogue/DSI/DALI
L3 Switch Dim /
Corridor Function
Maintenance
Disconnect luminaire
before undertaking any
maintenance or cleaning.
Cleaning should be
undertaken on external parts
of the luminaire only using a
slightly damp lint free cloth.
To remove rear housing
use a pan pozi screwdriver
to remove screws.
Use a pan pozi screwdriver
to remove components.
Please contact Dextra for
assistance with spare
component supply.
Driver
LED
Circuit
Battery
Module
1
2
3
4
5