Parts List

5.8 Grid Setup Menu 5.9 Generator Port Use Setup Menu
5.10 Advanced Function Setup Menu
For California only.
Grid Setting
Grid Mode
Grid Type
General Standard
UL1741IEEE1547
CPUC RULE21
SRD-UL-1741
120/240V Split Phase
120/208V 3 Phase
120V Single Phase
220V Single Phase
Grid
Set1
PF
Grid Frequency
Reconnection Time
Grid Vol High
Grid Vol Low
Grid HZ High
Grid HZ Low
Grid Setting
50HZ
60HZ
1.00060S
265.0V
185.0V
60.5Hz
59.3Hz
Grid
Set2
Grid Setting
Q(V) FW
Normal Ramp rate
Soft Start Ramp rate
VW
V1:0.0V Q1:0.00 Fstart:0.00Hz
Fstop:0.00Hz
Vstart:0.0V
Vstop:0.0V
0.0%/s
V2:0.0V Q2:0.00
V3:0.0V Q3:0.00
V4:0.0V Q4:0.00
0.0%/s
Grid
Set3
Grid Setting
L/HVRT
L/HFRT
HV2:0.0V
HV1:0.0V
LV1:0.0V
LV2:0.0V
LV3:0.0V
0.16S
0.16S
0.16S
0.16S
0.16S
HF2:0.00HZ
HF1:0.00HZ
LF1:0.00HZ
LF2:0.00HZ
0.16S
0.16S
0.16S
0.16S
Grid
Set4
Mode
OFF
ON
Generator Input
SmartLoad Output
Micro Inv Input
Gen connect to Grid input
On Grid always on
Ml export to Grid cutoff
GEN PORT USE
60Min
100%
95%
Power Open Delay
1000W
PORT
Set1
Clear Arc_Fault
Solar Arc Fault ON
System selfcheck
Gen peak-shaving
Power
7000W
Grid peak-shaving
Power
4000W
Advanced Function
Func
Set1
DC1 for WindTurbine
V1
V2
V3
V4
V5
V6
V7
V8
V9
V10
V11
V12
0V
0V
0V
0V
0V
0V
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
0V
0V
0V
0V
0V
0V
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
DC1 for WindTurbine
Advanced Function
Wind
Set2
Please select the correct Grid Mode in your local area. If
you are not sure, please choose General Standard.
Please select the correct Grid Type in your local area,
otherwise the machine will not work or be damaged.
Please select the correct Grid Frequency in your local area.
UL1741&IEEE1547,CPUC RULE21,SRD-UL-1741
No need to set the function of this interface.
General Standard
You can hole this in default value。
This is for WindTurbine
For California only.
Gen Peak-shaving---Enable When the power of the
generator exceeds the rated value of it, the inverter will
provide the redundant part to ensure that the generator
will not overload.
Grid Peak-shaving---Enable When the power of the grid
exceeds the set value, the inverter will provide the
redundant part to ensure that the grid power does not
exceed the set value.
System selfcheck ---Disable. this is only for factory.
Solar Arc Fault ON---This is only for US.
Genertor Input:use Genertor
SmartLoad Output: if the SOC is up than
“ON”and solar power is high than 1000W.
the inverter will open smartload.
On Grid always on:mean when have Grid,the
smartload will always on
Micro Inv Input:Inverter will open
Microinverter.if the SOC if below the“ON”
and close if the SOC if up than the“OFF”
- 27 - - 28 -