Settings Menu: 2-Speed Pump
Equipment circuits selected in this menu will automatically switch a two-speed filter pump to high speed when
these circuits are on. If a two-speed pump is assigned to solar, a cleaner or a pump, when activated the pump
will automatically run for five minutes in high speed then switch to low speed. For example, when on, the filter
pump will switch to high speed whenever the JETS or CLEANER is on. There must be a two-speed relay
installed in the EasyTouch Load Center in order for the “2-Speed Pump” menu settings to function.
2-Speed Pump
To configure a two-speed pump to a circuit:
Settings Menu: Solar
Use the solar settings to setup solar or configure solar as a heat pump: Setting Up Solar Control: Ensure
that the solar temperature sensor is installed.
About Installing Solar Heating: First, install the solar sensor at the collectors and connect to the EasyTouch
load center. If HEAT PUMP is selected and is being used in place of a solar heating system, install Solar
sensor near the EasyTouch Load Center. Connect the wires to the SOLAR screw terminals according to the
wiring diagram on page 64. Plug the solar valve actuator cable into three-pin socket marked VLV A on the
EasyTouch motherboard. If a solar booster pump is being installed, connect the pump to a power relay and
plug a low voltage cable from relay into the two-pin socket marked SOLAR on the EasyTouch motherboard.
Note: If Solar is not selected (No), the EasyTouch menu selections display “AUX EXTRA”
instead of “SOLAR.” This allows the solar plug (J17) on the EasyTouch motherboard to be used
an “extra” auxiliary output circuit. The Solar button is used to switch on and off the extra
auxiliary circuit.
To access the Solar menu:
MENU SETTINGS Solar Solar
Getting There
MENU SETTINGS 2-Speed Pump 2-Speed Pump
Getting There
2-Speed Pmp 1/4
Circuit:
[SPA HEATER ]
Up/Down buttons: Select a circuit that will switch the filter pump to high speed. You can set up to four circuits to use
a two-speed pump (1/4, 2/4, 3/4, 4/4).
Right button: Move to assign a circuit setting.
Up/Down buttons: Select the circuit to assign to a two-speed pump. The generic circuits names are: NONE, SPA,
POOL, AUX 1-7 (EasyTouch 8), AUX 1-3 (EasyTouch 4), FEATURE 1-8, SOLAR, HEATER, POOL
HEATER, SPA HEATER and FREEZE. AUX EXTRA is displayed only available if the Solar output (J17) plug on
the EasyTouch motherboard is not being used for solar equipment. Use the Solar button to switch the extra circuit on
and off (see page 5). Selecting NONE does not assign a circuit. Note: You can use a Feature circuit to change a 2-
Speed pump to hight speed.
Right button: Assign the next circuit (2/4).
Up/Down buttons: Select the first digit for the circuit number (1/4, 2/4, 3/4, 4/4).
Right button: Move to circuit setting.
Up/Down buttons: Select the next circuit. When finished press the Menu button.
Press the Menu button to save the settings and to return to the Settings menu options. Press the button again to return
to the main menu options or press again to return to the main screen.
Solar:
Press the Up/Down button to select which solar screen to
view. Press the Right
Press the Up/Down button to select which solar screen to view. Press the Right button to select the setting and
the Up/Down button to change a setting or value.
Screen (1/3): ENABLE SOLAR: Is the pool using solar heat? Select Yes or No to enable solar heat. To display
the solar selection as a heat source in the main screen, select Ye s.