User`s guide

41
EasyTouch Indoor Control Panel Installation and User’s Guide
Settings Menu: Delays (Spa/Pool (Heater Cool-Down) and Delays For Valves)
Setup which functions (pool/spa, and valves) to assign the delay feature. Delays can be assigned to the
following equipment.
Heater Cool-Down Delay Cancel: Shuts Filter Pump off immediately.
2-Speed Filter Pump five-minute START on HIGH SPEED Delay Cancel: Shifts pump to low
speed.
Automatic Pool Cleaner START Delay: Starts Cleaner Pump immediately, without normal delay in
which the filter pump first runs for 5 minutes.
Automatic Pool Cleaner SOLAR Delay: Allows Cleaner Pump to run even though solar delay has
shut it off for 5 minutes.
Some heaters require a cooldown cycle before being switched off. This can be setup to run the filter pump an
additional ten minutes to dissipate residual heat built up inside the heater combustion chamber. You can also
cancel the delay feature. For information about using the cancel delay feature, refer to “Delay Cancel” on
page 20.
Delays
Cooldown: No
Valves: No
MENU SETTINGS DELAYS DELAYS
Getting There
Solar 1/3
Enable: Yes
Heat Pump: No
Solar 3/3
Temperature Diff
Start: 6°
Run : 4°
Solar 2/3
Freeze Enbl: No
Night Cool : No
Press the Up/Down buttons to select YES to enable COOLDOWN delays for the pool and spa circuits.
Select YES to use delays for valves. Press the Menu button to save and to return to the Settings menu options.
HEAT PUMP: Is a heat pump being used for solar heat? Select Ye s or No to enable solar as a heat pump. Heat
Pump Control instead of Solar: Select YES if a heat pump is being used in place of a solar heating system. If Solar
is set to heat pump, Valve A is free for other circuits.
Right button: Select 2 of 3 (2/3) to access the freeze and night cooling features.
Screen (2/3): ENABLE FREEZE: Enable freeze protection when using solar heat. Select Ye s or No to enable
freeze solar protection.
ENABLE NIGHT COOLING: Select Yes or No to enable nocturnal cooling. Night cooling enabled (YES), will
circulate water through the system to lower the temperature during the night hours. Set the temperature in the Heat
menu. Note: If a heat pump is being used instead of a solar heating system (see above), select YES to enable solar as
a Heat pump.
Screen (3/3): Solar temperature differential start up and run settings.
Start: Set the temperature differential to start heating from 3° to 9°. For example, if “Start” is set to 3°, this ensures
that the temperature has to deviate by 3° at least to the specified set point temperature (in the Heat menu, on page 25)
before it switches on. Once the solar comes on it will start converging as it is heating. This ensures that it will not
continually be switching on and off.
Run: Set the temperature differential to stop heating from 2° to 5°. This setting sets how close to the target set point
temperature to switch off solar heat.
Press the Menu button to save the settings and to return to the Settings menu options. Press the button again to return
to the main menu options or press again to return to the main screen.
Delays: To assign a delay feature:
Delays Cooldown: This feature keeps the pump running for ten minutes after the heater is switched off to cool down the
heaters header andheat exchanger. Some heater models require this cool down period or damage will occur. This is
sometime referred toas the “Fireman Switch.” for example, If you are in the spa, and you switch it off. The IntelliTouch
will return the valvesto Pool” mode position. If the pool is running a cycle, or the Fireman switch (Spa/Pool Delay) is
enabled,colder water from the pool would be pumped into the spa as the valves turn. Note: If the pool is not running a
cycle,and the fireman switch is not enabled, the pump stops and no pool water would be pumped into the spa as the
valvesturn back to pool. Delays For Valves: This feature creates a 30 second PUMP OFF (forced) period anytime the
valves rotate. Either from poolto spa, or spa to pool. When you switch the spa off, even if the pool is running a cycle or
the fireman switch is enabled,it stops the pump for 30 seconds while the valves turn, so colder water from the pool will
not enter the spa. This featureprevents cold water entering the spa when you start the spa, so less heating is needed. It
also stops the pump when thesystem is changing from pool to spa or back again in Freeze mode.