User`s guide
63
EasyTouch Indoor Control Panel Installation and User’s Guide
Cabling the Indoor Control Panel at the Load Center
To connect the indoor control panel cable to the motherboard:
1. Turn off the main system power before making any connections.
2. Run a UL approved four conductor cable (22 AWG) from the indoor control panel to the Load
Center. The preferred wire color scheme is: Red, yellow, green, and black.
3. Route the cable up through the low voltage raceway to the motherboard.
4. Strip back the communication cable conductors ¼ in. Insert the wires into the screw terminals
(provided in the kit). Secure the wires with the screws. Make sure to match the color-coding of the
wires: Red = +15, Yellow = +DT, Green = -DT, and GND = Black.
5. Insert the cable plug onto the COM-PORT (J20) connector.
6. Proceed with Mount and Cable the Indoor Control Panel, page 64.
COM PORT
(J20)
Indoor Control Panel
IntelliChlor
IntelliFlo
RF Transceiver
EasyTouch Motherboard