Manual
3.2.2  Hold the "MODE" key for 1 second and the digital tube flashes for 5 seconds to display the battery voltage; 
3.3  Digital adjustment and parameter setting: 
(Forewarned:Push Down The Knob Is  “OK<Confirm>”,Clockwise Rotation The Knob One Pulse Is” + <Add>”, 
Anticlockwise Rotation The Knob One Pulse Is” - <Minus>”) 
3.3.1  Short Press  “OK” To Save The Output Value,Digital Tube Display "..." After loosening, Saved Successfully, The 
Output Value Is This Saved Value After The Next Boot; When We Debug The Device, We Need To Adjust The 
Output Value Randomly, As Long As The Knob Is Not Pressed, It Will Still Be The Saved Value After Rebooting; 
3.3.2  Hold The “OK” For 2 Seconds To Enter The Setting State.,Display”F001”(Parameter Number 001); 
3.3.3  Turn the knob to change the parameter number, You need to enter a password when enter F002 or F100: 
3.3.3.1  F001->F002 enter a password“+ - - +(Turn the knob)” ,Then press the knob to enter; 
3.3.3.2  F001->F100 enter a password“+ - + -(Turn the knob)” ,Then press the knob to enter; 
3.3.4  Press "Ok" to enter the setting of corresponding parameter value, and turn the knob to modify parameters; 
3.3.5  Press "Ok" to save the parameter, exit the parameter setting, and display the next parameter number (after 
setting the F001 value without entering the password, the normal operation screen will enter); 
3.3.6  Rotate the knob directly to the last parameter number, press the "OK" key, and the setting is completed; 
3.3.7  If no operation on the parameter setting screen exceeds 10s, it will exit the setting state; 
3.4  Voltage setting parameters. please read section 3.4 before operating, especially to enter a password: 
3.5  Current setting parameters. please read section 3.4 before operating, especially to enter a password: 
4  current problem detection: the possibility of the current not output is very small,you can measured the voltage of 
4-AIO  6-GND with a multimeter, if it is >20V, than current file of your multimeter is broken or gear is wrong, because 
there are voltage must be current, try change a multimeter, multimeter current file inside a fuse is easy to burn; 
5  Please Read This Manual Carefully Before Wiring, Turn Off The Power And Then Connect; 
Number  Description  Note  Default
F001  Adjust Mode  0:Coarse  1:Fine  2: Point Mode(Need to set F100>0)  0 
F002  Output Mode 
0:±10V  1:±5V 2:0-10V 3:2-10V  4:0-5V  5:1-5V 6:0-
3.3V  
7:0-2.5V  8:0-1V  9:-10V-0V 
2 
F003  Display Mode  0:Real Voltage  1:Percentage 0-100.0%  2:50HZ  3:1500  0 
F004  Add Or Sub Num For 
Knob’s Pulse(Coarse) 
1-50 
No Decimal Point Concept  (1-50)×10 
1 
F005  Add Or Sub Num For 
Knob’s Pulse ( Fine) 
1-50 
No Decimal Point Concept  (1-50)×1 
1 
F006  -10V Calibration Value
-199 -- +199 Internal Reference,Please Be Careful   
F007  0V Calibration Value  -199 -- +199 Internal Reference,Please Be Careful   
F008  +10V Calibration Value
-199 -- +199 Internal Reference,Please Be Careful   
F100  Point Mode Num  0: Point Mode Not Use  2-9: Point Num  0 
F101…F109
Point Output Value  range : -10V to 10V You can set as many values as there are 
points 
Number  Description  Note  Default
F001  Adjust Mode  0:Coarse  1:Fine  2: Point Mode(Need to set F100>0)  0 
F002  Output Mode  0:0-20mA  1:4-20mA  2:0-22mA  0 
F003  Display Mode  0:Real Voltage  1:Percentage 0-100.0%  2:50HZ  0 
F004  Add Or Sub Num For 
Knob’s Pulse(Coarse)
1-50 
No Decimal Point Concept  (1-50)×10 
1 
F005  Add Or Sub Num For 
Knob’s Pulse ( Fine) 
1-50 
No Decimal Point Concept  (1-50)×1 
1 
F008  Calibration Value  -999 -- +999 Internal Reference,Please Be Careful   
F100  Point Mode Num  0: Point Mode Not Use  2-9: Point Num  0 
F101…F109
Point Output Value  range : 0-22mA  You can set as many values as there are points   