Datasheet
ICP-10111 
Document Number: DS-000177  Page 9 of 31 
Revision: 1.3 
3.2  ABSOLUTE MAXIMUM RATINGS 
Stress levels beyond those listed in Table 6 may cause permanent damage to the device. These are stress ratings only and functional 
operation of the device at these conditions cannot be guaranteed. Exposure to the absolute maximum rating conditions for 
extended periods may affect the reliability of the device. 
PARAMETER 
RATING 
Supply voltage, VDD 
-0.3V to 2.16V 
Supply Voltage, SCL & SDA 
-0.3V to VDD 0.3V 
Operating temperature range 
-40°C to 85°C 
Storage temperature range 
-40°C to 125°C 
ESD HBM 
2.0 kV 
ESD CDM 
250V 
Latch up, JESD78 Class II, 85°C 
100 mA 
Overpressure 
>600kPa 
Table 6. Absolute Maximum Ratings 
3.3  SENSOR SYSTEM TIMING 
Default conditions of 25°C and 1.8V supply voltage apply to typ. values listed in Table 7, unless otherwise stated. Max. values apply 
over the specified operating range of VDD and over the operating temperature range. 
PARAMETER 
SYMBOL 
CONDITIONS 
MIN 
TYP 
MAX 
UNITS 
COMMENTS 
Power-up time 
t
PU
After hard reset, V
DD
 ≥ V
POR
- 
170 
- 
µs 
Time between V
DD
 reaching V
PU
and sensor entering idle state 
Soft reset time 
t
SR
After soft reset 
- 
170 
- 
µs 
Time between ACK of soft reset 
command and sensor entering 
idle state 
Measurement duration 
t
MEAS
LN Mode 
- 
20.8 
23.8 
ms 
Duration for a pressure and 
temperature measurement 
Table 7. System Timing Specifications 