12. Place another flat washer on each of the four studs protruding from the mounting
plate.
13. Place a lock washer over the flat washer on each of the four studs.
14. Place a nut on each of the four studs protruding from the mounting plate and
tighten with a 11/32 inch nutdriver.
A
B
Connect
extension
cables here
D
C
Orange
Orange
Figure 2-5
15. Connect the plain black and plain brown wires to the cable extension with the
smaller spade lug (part #6105-398) (C on Figure 2-5).
16. Connect the cable extension assembly from the step 17 to the fuse holder. You may
need to compress the spade lug with a pair of pliers.
17. Connect the black/white and the brown/white wires to the cable extension with the
larger spade lug (part #6105-399 (D on Figure 2-5).
18. Connect the cable extension assembly from step 19 to the power input module
(former connection of the old white transformer lead).
19. Connect the orange lead wires to the rectifier bridge (B on Figure 2-5).
20. Connect the MATE-N-LOCK transformer connector (A on Figure 2-5).
21. Secure all loose wires with the four provided tie wraps.
22. Replace the transformer case cover and secure with the four transformer case
screws. Tighten in place.
23. Place the retrofit label on the cover of the transformer case.
24. Reconnect the PA/4000’s power cable.
25. Turn the POWER switch to the ON position.
26. Make sure the hand-held display reads ALL OK.