Specifications

Technician’s Guide 2-50
SETUP SWITCH 1 2 3 4 5 6
78
OFF OFF OFF OFF OFF OFF OFF OFF
This line contains the positions of the PA/4000’s DIP switches.
ANALOG INPUT VALUES:
PAPER: 236 EDGE: 184 TEMP: 064
POT ADJ: 139 BAT VOL: 204
These lines list the values of the sensors and adjustment potentiometers within the
Printer.
INCH COUNTER DATE SET 11/14/94
TOTAL LABEL LENGTH IN INCHES 000000170
These lines contain the Printers internal counter information. It includes the counter set
date and the total amount in inches (10 inch increments) of labels printed.
2.5.3 APPLICATOR RESET
1. Turn the PA/4000’s power switch to the ON position.
2. Press and hold the following keys in this order: 2nd, STOP/CLEAR, FEED
3. Release all three keys simultaneously.
4. Press the MENU key. (The ERROR LED will blink).
2.5.4 PRODIGY PLUS RESET
1. Turn the PA/4000’s power switch to the ON position.
2. Press and hold the following keys in this order: 2nd, STOP/CLEAR, FEED
3. Release all three keys simultaneously.
4. Press the STOP/CLEAR key. (The ERROR LED will blink).