Specifications

PA/4000 User’s Manual
Section 4, Installation
Page 11
4.10 Mounting the Photosensor
The distance between the photosensor and the PA/4000 is not crucial. A good guideline
is to place the photosensor as close as possible to the applicator.
Parts: 1 Diagraph photosensor kit P/N 5700-216
Assembly: 1. Mount the photosensor to the conveyor using
the bracket and hardware provided. Position the
photosensor where it will not be tripped by the
next product prior to completion of the product
delay on the first product. Improper positioning
will result in missed products. Adjust the
sensing distance of the photosensor with the
potentiometer at the rear of the photosensor.
2. Tighten screws with a Phillips screwdriver and a
5/16-inch wrench.
3. Measure the distance from the photosensor to
the peel blade on the print engine and record
this measurement on the PA/4000 Configuration
sheet, see Section 6. You will need this
information later during the configuration of this
system.
4. Make sure the power is OFF and connect the
photosensor to J2 on the electrical panel on the
back of the print engine, see Section 4.12.