Specifications

PA/4000 User’s Manual
Section 5, Configuration
Page 2
5.1.2 Configuring the Power Module for the 220/240VAC Application
Failure to use proper fuses and/or install the fuse assembly for correct voltage can
damage the PA/4000.
Disconnect the power cord before servicing the power module.
Pop the fuse assembly up and out of the power module with a flat head screwdriver.
Once out of the power module, turn the fuse assembly so that the arrow on the
220/240VAC side of the assembly is lined up with the arrow on the power module.
Replace the fuse assembly.
See Fuse Replacement Kit Instructions 6105-404N when needing to replace a fuse.
!