Specifications

PA/4000 User’s Manual
Section 5, Configuration
Page 18
5.5 Example Job Setup
The following section shows an example job setup based on PA/4010.
NOTE: Move the PA/4000 away from the line until your Hand-Held
Terminal settings are correct.
STEP 1: After system installation and configuration, check for any errors. If the
system is operating normally, the screen will display ALL OK.
STEP 2: Go to the Menu screen.
Press the MENU/SELECT key or the down arrow key. This will take you
to the Menu screen.
STEP 3: Clear the Item Count.
Press the MENU/SELECT key once to enter edit (flashing) mode.
Use the arrow keys to enter a Clear Count response of YES or NO.
TO ACCEPT CHANGES: Press the MENU/SELECT key.
TO CANCEL: While the display is still flashing, press and hold the 2nd
key followed by the MENU/SELECT key.
STEP 4: Set the Tamp Dwell value.
From the Clear Count screen, press the down arrow key once.
Press the MENU/SELECT key once to enter edit (flashing) mode.
For example, use the arrow keys to enter a Tamp Dwell value of 80.
TO ACCEPT CHANGES: Press the MENU/SELECT key.
TO CANCEL: While the display is still flashing, press and hold the 2nd
key followed by the MENU/SELECT key.
STEP 5: Set the Product Delay.
From the Tamp Dwell screen, press the down arrow key once.
Press the MENU/SELECT key once to enter edit (flashing) mode.
Use the arrow keys to enter a Product Delay In value of 100.
TO ACCEPT CHANGES: Press the MENU/SELECT key.
TO CANCEL: Press and hold the 2nd key followed by the
MENU/SELECT key.
STEP 6: Set the Output Delay .
From the Product Delay screen, press the down arrow key once.
Press the MENU/SELECT key once to enter edit (flashing) mode.
Use the arrow keys to enter an Output Delay value of 0.
TO ACCEPT CHANGES: Press the MENU/SELECT key.
TO CANCEL: Press and hold the 2nd key followed by the
MENU/SELECT key.