5.1.3.3 Connection mode
For this measurement the DUT was supplied by 3 V. FW was downloaded and the JTAG
programmer was disconnected and connection with an iPhone 4S was established.
Table 14: Peak current during Connection mode
Parameter
I
PEAK
(mA)
Ipeak, TX
16.74
Figure 38: Supply current during a Connection frame