6.5.5 CNMOI – Configuration Monitor Initiate
Synopsis
This command initiates the monitoring of an object on the Signaling Gateway. An object is currently a
C7LINK.
For signaling, the STS monitors information sent from the EQU of the signaling link and the RTS monitors
information received by the signaling link.
Syntax
CNMOI:C7LINK=,STS=,RTS=;
Prerequisites
If specified, the C7LINK has already been initiated and must have a TS and EQU.
The PCM on which STS exists must have already been initiated and STS must be within the correct range
for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).
The PCM on which RTS exists must have already been initiated and RTS must be within the correct range
for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).
STS is not already assigned elsewhere on the system for output.
RTS is not already assigned elsewhere on the system for output.
A signaling link can only be monitored once.
Attributes
CONFIG
Examples
CNMOI:C7LINK=1,STS=3-3-15,RTS=5-3-16;
6.5.6 CNMOE – Configuration Monitor End
Synopsis
This command ends the monitoring of an object. An object is currently only an signaling link.
Syntax
CNMOE:C7LINK=;
Prerequisites
The C7LINK is being monitored.
Attributes
CONFIG
Examples