Understanding LED Signals 
LEDs on the Mounting Bracket
The LEDs on the mounting bracket provide 
information about the status of the different systems 
on the board. To identify and locate these LEDs, see 
Figure 4.
Figure 4. End Panel LEDs
The following tables describe how the end panel 
LEDs provide information:
Board Status LED
Channel LEDs
LEDs on the Brooktrout Fax Board
The LEDs on the board provide information about the 
status of the board. To locate these LEDs, see 
Figure 5. 
The following table describes how the LEDs on the 
board provide information: 
* DSP1 and its associated LED are only loaded 
on the 8-channel version of the board.
Figure 5. Dialogic® Brooktrout® TR1034 Analog PCI 
Express Series Board
Using the TR1034 Analog 
Board
Once you have installed the TR1034 Analog board, 
install and configure your fax or voice software 
application according to instructions included with 
the software.
Getting Help
Dialogic provides technical support for customers 
who have purchased hardware or software products 
from Dialogic. If you purchased products from a 
reseller, please contact that reseller for technical 
support.
This equipment contains no user serviceable parts and 
is not intended for repair by unauthorized personnel.
If you experience problems with the TR1034 Analog 
board, please use the web site below for repair or 
warranty information. If the equipment is causing 
harm to the telephone network, the telephone 
company might request that you disconnect the 
equipment until the problem is resolved.
www.dialogic.com/support/
Copyright and Legal Notice
Copyright © 2006-2008] Dialogic Corporation. All Rights Reserved. You may not 
reproduce this document in whole or in part without permission in writing from Dialogic 
Corporation at the address provided below.
All contents of this document are subject to change without notice and do not represent a 
commitment on the part of Dialogic Corporation or its subsidiaries. Reasonable effort is 
made to ensure the accuracy of the information contained in the document. However, due 
to ongoing product improvements and revisions, Dialogic Corporation and its subsidiaries 
do not warrant the accuracy of this information and cannot accept responsibility for errors 
or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH 
DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR 
OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS 
DOCUMENT. EXCEPT AS EXPLICITLY SET FORTH BELOW OR AS PROVIDED IN A 
SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO 
LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED 
WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS 
INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A 
PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY 
INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life sustaining, critical 
control or safety systems, or in nuclear facility applications.
It is possible that the use or implementation of any one of the concepts, applications, or 
ideas described in this document, in marketing collateral produced by or on web pages 
maintained by Dialogic Corporation or its subsidiaries may infringe one or more patents or 
other intellectual property rights owned by third parties. Dialogic Corporation or its 
subsidiaries do not provide any intellectual property licenses with the sale of Dialogic 
products other than a license to use such product in accordance with intellectual property 
owned or validly licensed by Dialogic Corporation or its subsidiaries. More detailed 
information about such intellectual property is available from Dialogic Corporation's legal 
department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. 
The software referred to in this document is provided under a Software License 
Agreement. Refer to the Software License Agreement for complete details governing the 
use of the software.
Dialogic Corporation encourages all users of its products to procure all necessary 
intellectual property licenses required to implement any concepts or applications and does 
not condone or encourage any intellectual property infringement and disclaims any 
responsibility related thereto. These intellectual property licenses may differ from country 
to country and it is the responsibility of those who develop the concepts or applications to 
be aware of and comply with different national license requirements.
Dialogic, Dialogic Pro, Brooktrout, Cantata, SnowShore, Eicon, Eicon Networks, 
Eiconcard, Diva, SIPcontrol, Diva ISDN, TruFax, Realblocs, Realcomm 100, NetAccess, 
Board Status LED Meaning
Flashing yellow
(1.5 second rate)
Board is powered up and is 
passing self-test checks.
Steady red Board is powered up, but the 
self-test has failed.
Flashing yellow 
and green
Board is powered up and is 
downloading firmware.
Flashing green
(1 second rate)
Firmware is downloaded, and the 
board is in service.
Solid green Board is hung, needs to be reset.
Flickering red Board has failed, needs to be reset.
Off Board has no power, or board is 
hung and needs to be reset.
Channel LEDs Meaning
Off Channel is on hook.
Flashing at 0.5 second rate Channel is off hook.
Flashing at Ring Cadence
*
* Ring Cadence varies country by country.
Incoming ring signal.
RJ-45 Connector A
RJ-45 Connector B
Channel LEDs
Board Status LED
LED Meaning
DSP0 Displays the status for DSP0 that supports the 
four ports on the A connector (RJ-45). After 
the firmware is loaded and during normal 
execution, this LED blinks about every 
second. If the LED is not blinking, the DSP0 
firmware is not running.
DSP1* Displays the status for DSP1 that supports the 
four ports on the B connector (RJ-45). After 
the firmware is loaded and during normal 
execution, this LED blinks about every 
second. If the LED is not blinking, the DSP1 
firmware is not running. 
Power Steady green indicates good board power.
PCI Express Connector
Board LEDs
(DSP0,
DSP1,
Power
Module Number Switch
Mounting Bracket
Connector A
Connector B
(8-channel only)
Channel LEDs
Board Status
LED
Eight-channel Board