User`s guide
Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 302
Dialogic Corporation
Resolved IPY00006647 36598 98 DM3 Firmware There is memory corruption on the Dialogic
®
DMV1200BTEP Board when using ISDN firmware.
The memory corruption is caused by any of the
following conditions:
• Facility IE in the inbound SETUP > 128 bytes
• Several call scenarios causing a memory leak:
- Incoming SETUP message with an active call on
the specified bearer channel
- Incoming SETUP message while the channel is
BLOCKED (i.e., application has not issued
gc_WaitCall( ))
- SETUP glare condition
- Disconnect glare
Resolved IPY00011347 34397 56 DM3 Hardware The general network interface alarm LED on the
Dialogic
®
DMV1200BTEP and DMV600BTEP Boards
is always on after DCM is started. Even after
unplugging the E1 cable, there is no change; the LED
is still on.
Resolved IPY00038998 -- 160 DM3 Host Runtime
Library
Bipolar violation alarms are reported in LineAdmin, but
are not reported programmatically via GCAMS.
Resolved IPY00030905 34640 56 DM3 Host Runtime
Library
When Service Update 30 is installed on the System
Release 6.0 PCI Windows base release, if
ms_open( ) is called, it causes Microsoft Visual C++
Runtime Library errors. This does not happen when
Service Update 30 is installed on a clean system.
Resolved IPY00010478 33053 18 DM3 Host Runtime
Library
During a hold glare scenario, the application never
receives a GCEV_HOLDREJ event.
Resolved IPY00009554 32913 18 DM3 Host Runtime
Library
The application doesn’t receive a
GCEV_UNBLOCKED event after an alarm is cleared.
Resolved IPY00008893 32725 18 DM3 Host Runtime
Library
An ERR entry for circular buffer underruns occurs
when the streaming to board feature is used on a
Dialogic
®
DM/V960A-4T1 Board. This causes the
rtflog file to roll over more quickly, thus losing valuable
data.
Resolved IPY00008422 33443 18 DM3 Host Runtime
Library
The dx_stopch( ) function does not return when
called synchronously.
Resolved IPY00006779 34516 56 DM3 Host Runtime
Library
When sr_putev( ) is used to add an event to the run-
time library, if the parameter evtlen is set bigger than
512, the application receives an exception error.
Resolved IPY00012770 28838 -- DM3 Install Windows
®
device manager (WDM) unable to load
dlgcdm3_nt4.inf for Dialogic
®
DI/0408-LS-A and
DI/SI32 Rev 2 Boards.
Resolved IPY00032239 36769 98 DM3 IP There is a problem when using IPPARM_SIP_HDR to
set call ID.
Resolved IPY00031791 36793 98 DM3 IP gc_InvokeXfer( ) fails to send a SIP REFER
message, and no event or failure indication is returned
to the application.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description