Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board September 2010 64-0430-04 Rev A www.dialogic.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Copyright and legal notices Copyright © 2007-2010 Dialogic Corporation. All Rights Reserved. You may not reproduce this document in whole or in part without permission in writing from Dialogic Corporation at the address provided below.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Revision history Revision Release date Notes 9000-62363-10 September 2003 SRR, SS7 4.0 Beta 9000-62363-11 May 2004 SRR, SS7 4.0 9000-62363-12 August 2004 SRR, SS7 4.1 9000-62363-13 April 2005 LBG 9000-62363-14 July 2008 LBG, SS7 5.0 64-0430-01 July 2009 LBG, SS7 5.1 64-0430-02 May 2010 LBG 64-0430-03 July 2010 LBG 64-0430-04 Rev A September 2010 LBG Last modified: September 9, 2010 Refer to www.dialogic.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Table of Contents Table of Contents ....................................................................................................... 4 Introduction .............................................................................................................. 5 Configuring the hardware ............................................................................................ 6 Installing the board .......................................
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Introduction The Dialogic® TX 4000 PCI SS7 Network Interface Board provides four T1 or E1 digital trunk interfaces and two Ethernet 10/100Base-T interfaces. For more information, refer to the Dialogic® TX 4000 PCI SS7 Network Interface Board Installation Manual available on www.dialogic.com.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Step Description For details, refer to... 11 If applicable, connect the Ethernet interfaces for board redundancy, to a SIGTRAN network, or both. Connecting TX boards for redundancy on page 13 12 Verify that the TX 4000 board is operational. Interface status LEDs on page 16 Board status LEDs on page 17 Configuring the hardware Before installing the TX 4000 board, use the following procedures to configure H.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board ON 1 2 3 4 56 7 8 OFF S2 ON 1234 S3 The following illustration shows the default settings for the TX 4000 DIP switches (H.100 bus termination and SS7 Monitor mode disabled): OFF Configuring SS7 Monitor mode DIP switch S3 controls the SS7 Monitor mode. By default, all S3 switches are set to the ON position. This setting disables Monitor mode. When Monitor mode is disabled, the TX board is an active participant in the network.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Installing the board Complete the following steps to install the TX 4000 board: 1. If necessary, configure the board as described in Configuring the hardware on page 6. 2. Power down the computer and disconnect the power cord from the power source. Remove the cover from the computer and set it aside. 3. If you are placing the board into a PCI chassis, remove the PCI retainer bracket by unscrewing it from the board.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Assigning a CP number Use the txcpcfg utility to assign a CP number. Depending on the operating system environment, the txcpcfg utility is located in the following directory: • Windows: Program Files\Dialogic\tx\bin\ • UNIX: /opt/dialogic/tx/bin/ Complete the following steps to assign a CP number: 1. Power up the system if it is not running.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Establishing network connections Before connecting the board to a network, refer to www.dialogic.com/declarations/default.htm for information on the current approvals. The trunk connectors and the Ethernet connectors are located on the PCI end bracket as shown in Interface status LEDs on page 16.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Connecting to the network Before connecting a TX 4000 board to the network, ensure that you have properly configured the trunks as either T1 or E1. For configuration information, refer to the Dialogic® NaturalAccess™ Signaling Software Configuration Manual. Caution: Dialogic obtains board-level approval certificates for supported countries.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board E1 network considerations TX 4000 boards can support up to four CEPT E1 trunk interfaces. For typical E1 communications, each E1 interface connects directly to an E1 trunk, as shown in the following illustration: TX 4000 Public service telephone network or proprietary network E1 trunk Note: Trunks do not synchronize until the board is booted with a valid E1 configuration.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Connecting TX boards for redundancy Use the redundancy feature to enable the system to detect and recover from the failure of signaling links on a TX 4000 board, the failure of a signaling node, or the failure of the TX 4000 board itself. In a redundant configuration, each pair of TX boards is connected through a private Ethernet connection. If other devices are connected to the private Ethernet link, avoid overloading the link.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Single-node redundant signaling server The following illustration shows how to set up two TX 4000 boards based on the single-node signaling server in a TDM configuration. The boards are located in the same chassis to ensure board-level redundancy.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Dual-node redundant signaling server The following illustration shows how to set up two TX 4000 boards based on a dualnode redundant signaling server in an IP network configuration. The boards are located in two separate chassis to ensure board-level and system-level redundancy.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Interface status LEDs The TX 4000 board provides LEDs to indicate the status of the trunk and Ethernet interfaces.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Board status LEDs On the back of the TX 4000 board, banks of LEDs (D6-D21) indicate the current status of the board. The following illustration shows the board status LEDs: D7 D11 D15 D17 D6 D10 D14 D16 D9 D8 D13 D12 D19 D18 D21 D20 Boot code LEDs Status LEDs Boot code LEDs Boot code LEDs are active when the TX 4000 board is powered up. These LEDs progress through a series of red codes.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Compliance statements EU R&TTE statement This product is intended to be connected to a 2048 kbit/s 75 ohm or 120 ohm digital structured or unstructured ONP leased line in all EU countries. For more information, refer to www.dialogic.com/declarations/default.htm. FCC Part 15 Class A statement This board has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. This product is not intended for customer repair. Canadian ICES-003 statement This Class A digital apparatus complies with Canadian ICES-003.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Compliance with the R&TTE Directive The R&TTE Directive includes its own safety and EMC requirements. Although equipment declared compliant to the R&TTE Directive does not require explicit declaration of conformity to EMC and Low Voltage Directives, the above conditions must also be met to satisfy the safety and EMC requirements of the R&TTE Directive.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board [Ελληνική] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Dialogic Corporation ΔΗΛΩΝΕΙ ΟΤΙ ITE ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/EK, 2004/108/EK, 2006/95/EK. [Français] Par la présente Dialogic Corporation déclare que l'appareil ITE est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE, 2004/108/CE, 2006/95/CE.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board [Slovensko] Dialogic Corporation izjavlja, da je ta ITE v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES, 2004/108/ES, 2006/95/ES. [Slovensky] Dialogic Corporation týmto vyhlasuje, ~e ITE spĺňa základné po~iadavky a vaetky prísluané ustanovenia Smernice 1999/5/ES, 2004/108/ES, 2006/95/ES.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board South Korea 명 칭 ( 모 델 명 ) : TX4000 인 증 번 호 : TE-A62/K900-04-0324 인증받은자의 상호 : Dialogic Corporation 제 조 년 월 일 : Marked on serial number tag 제 조 자 / 제 조 국 : Made in USA Class A statement This Class A digital apparatus meets all requirements of the Korean EMI regulations. A급 기기 (업무용 방송통신기기) 이 기기는 업무용(A급)으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board China 24 Dialogic Corporation
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Dialogic Corporation 25
Installing a Dialogic® TX 4000 PCI SS7 Network Interface Board Product declarations and global approvals For information about product declarations and global approvals, refer to www.dialogic.com/declarations/default.htm. RoHS Statement For information about RoHS compliance for this product, refer to www.dialogic.com/rohs/default.htm.