Instruction manual
Copyright ©2006 Diamond Traffic Products
ALL RIGHTS RESERVED
61
Phoenix II/Unicorn/Pegasus 25 Pin Female Serial Interface Cable
Phoenix II/Unicorn/Pegasus 9 Pin Connector (front
view)
25 Pin Female Sub-D Connector
#7 – Receive Data (RXD)
#2 – Transmit Data (TXD)
#6 – Carrier Detect (DCD)
#20 – Data Terminal Ready (DTR)
#5 – Data Terminal Ready (DTR)
#6 – Data Set Ready (DSR)
#4 – Ready To Send (RTS)
#8 – Carrier Detect (DCD)
#3 – Serial Port Enabled (ENA)
#5 – Clear To Send (CTS)
#2 – Signal Ground (GND)
#1 – Frame Ground (GND)
#8 – Transmit Data (TXD)
#7 – Signal Ground (GND) (Shield)
#9 – Clear To Send (CTS)
#3 – Receive Data (RXD)
#4 – Ready To Send (RTS)
NOTE: On the Phoenix II/Unicorn/Pegasus 9 Pin connector, pin #1 is not used, pins #5 and pin #2 get two wires, and
pins #3 and #2 are shorted together.
Phoenix II/Unicorn/Pegasus 9 Pin Female Serial Interface Cable
Phoenix II/Unicorn/Pegasus 9 Pin Connector (front
view)
9 Pin Female Sub-D Connector
#7 – Receive Data (RXD)
#3 – Transmit Data (TXD)
#6 – Carrier Detect (DCD)
#4 – Data Terminal Ready (DTR)
#5 – Data Terminal Ready (DTR)
#6 – Data Set Ready (DSR)
#1 – Carrier Detect (DCD)
#4 – Ready To Send (RTS)
#8 – Clear To Send (CTS)
#3 – Serial Port Enabled (ENA)
#5 – Signal Ground (GND)
#2 – Signal Ground (GND)
(Shield)
#8 – Transmit Data (TXD)
#2 – Receive Data (RXD)
#9 – Clear To Send (CTS)
#7 – Ready To Send (RTS)
NOTE: On the Phoenix II/Unicorn/Pegasus 9 Pin connector, pin #1 is not used, pins #5 gets two wires, and pins #2
and #3 are shorted together.