Specifications

Cascade Modem Manual
Copyright © 2007 Diamond Traffic Products, Inc
Page 18
&Gn Maximum Data Rate Selection
n=3 1200 bps
n=4 2400 bps
n=5 4800 bps
n=6 7200 bps
n=7 9600 bps
n=8 12000 bps
n=9 14400 bps
n=10 16800 bps
n=11 19200 bps
n=12 21600 bps
n=13 24000 bps
n=14 26400 bps
n=15 28800 bps
n=16 31200 bps
n=17 33600 bps
&Hn Protocol Selection
n=0 V.90 with auto fallback to 300 bps *
n=1 V.90 with fallback to 28,800 bps
n=2 V.34 with automatic fallback to 300 bps
n=3 V.34 only (33,600 bps to 2400 bps)
n=4 V.32bis w/Automatic fallback to 300 bps
n=5 V.32bis only (14,400 to 4800) bps
n=6 V.22bis (2400 or 1200 bps)
n=7 V.22 (1200 bps)
n=8 Bell 212 (300 bps)
n=9 Bell 103 ( 300 bps)
n=10 V.21 (300 bps)
n=11 V.23 (1200/75 bps)
&S Display current AT& settings.
&Tn Modem Test Modes
n=0 Cancel Test Mode
n=3 Initiate Analog Loopback
&Z Sleep Mode; wake on Incoming Ring
%B Report Blacklisted Numbers
%C V.42bis Data Compression
N=0 Data Compression Disabled *
N=1 Bidirectional Data Compression Enabled
N=2 Data Compression Transmit Only
N=3 Data Compression Receive Only
%On Answer Mode
n=1 Answer in Answer Mode*
n=2 Answer in Originate Mode
%Vn Shared Line Use
n=0 No auto detection of local line status*
n=2 Check line voltage before going off-hook.
“NO LINE” response if line is unavailable
and “LINE IN USE” if line is off hook.
%$ - Display current AT% settings.
\Bn Character Length
n=0 6N1; 6 data bits, no parity, 1 stop bit
n=1 7N1; 7 data bits, no parity, 1 stop bit
n=2 7P1; 7 data bits, 1 stop bit, parity set by
“AT\P” command
n=3 8N1; 8 data bits, no parity, 1 stop bit, *
n=5 8N1; 8 data bits, 1 stop bit, parity set by
“AT\P” command
n=6 8X1; 8 data bits, 1 stop bit, 1 escape bit
enabling 9
th
bit escape mode.
\Nn Error Control Mode
n=1 Normal Mode
n=2 MNP Required
n=3 V.42 auto reliable mode *
n=4 LAPM required for connection
n=5 V.42 or MNP required
\Pn Parity Setting
n=0 Even Parity selected*
n=1 Space Parity selected
n=2 Odd Parity selected
n=3 mark Parity selected
\Qn Modem to DTE Flow Control
n=0 No Flow Control
n=2 CTS Flow Control only *
n=3 RTS/CTS Flow Control
n=4 XON/XOFF Flow Control